No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
snmpNotifyTable

snmpNotifyTable

This table is used to select management targets which should receive notifications, as well as the type of notification which should be sent to each selected management target.

The index of this table is snmpNotifyName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.6.3.13.1.1.1.1

snmpNotifyName

SnmpAdminString (SIZE(1..32))

Not-accessible

The locally arbitrary, but unique identifier associated with this snmpNotifyEntry.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.6.3.13.1.1.1.2

snmpNotifyTag

SnmpTagValue

Read-create

This object contains a single tag value which is used to select entries in the snmpTargetAddrTable. Any entry in the snmpTargetAddrTable which contains a tag value which is equal to the value of an instance of this object is selected. If this object contains a value of zero length, no entries are selected.

Currently, the maximum access is read-only.

1.3.6.1.6.3.13.1.1.1.3

snmpNotifyType

INTEGER {

trap(1),

inform(2)

}

Read-create

This object determines the type of notification to be generated for entries in the snmpTargetAddrTable selected by the corresponding instance of snmpNotifyTag. This value is only used when generating notifications, and is ignored when using the snmpTargetAddrTable for other purposes.

If the value of this object is trap(1), then any messages generated for selected rows will contain Unconfirmed-Class PDUs.

If the value of this object is inform(2),then any messages generated for selected rows will contain Confirmed-Class PDUs. Note that if an SNMP entity only supports generation of Unconfirmed-Class PDUs (and not Confirmed-Class PDUs),then this object may be read-only.

Currently, the maximum access is read-only.

1.3.6.1.6.3.13.1.1.1.4

snmpNotifyStorageType

StorageType

Read-create

The storage type for this conceptual row. Conceptual rows having the value "permanent" need not allow write-access to any columnar objects in the row.

Currently, the maximum access is read-only.

1.3.6.1.6.3.13.1.1.1.5

snmpNotifyRowStatus

RowStatus

Read-create

The status of this conceptual row.

To create a row in this table, a manager must set this object to either createAndGo(4) or createAndWait(5).

Currently, the maximum access is read-only.

Creation Restriction

The entries in this table can be created.

Modification Restriction

The entries in this table can be modified

Deletion Restriction

The entries in this table can be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation