MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
mplsLdpLspFecTable

mplsLdpLspFecTable

This is a table which shows the relationship between LDP LSPs and FECs.

The indexes of this table are mplsLdpEntityLdpId, mplsLdpEntityIndex, mplsLdpPeerLdpId, mplsLdpLspFecSegment, mplsLdpLspFecSegmentIndex and mplsLdpLspFecIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.2.1.10.166.4.1.3.10.1.1

mplsLdpLspFecSegment

INTEGER {inSegment(1),outSegment(2)}

Not-accessible

If the value is inSegment(1), then thisindicates that the following index, mplsLdpLspFecSegmentIndex, contains the same value as the mplsInSegmentLdpLspIndex.

Otherwise, if the value of this object is outSegment(2), then this indicates that following index, mplsLdpLspFecSegmentIndex, contains the same value as the mplsOutSegmentLdpLspIndex.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.166.4.1.3.10.1.2

mplsLdpLspFecSegmentIndex

MplsIndexType

Not-accessible

This index is interpretted by using the value of the mplsLdpLspFecSegment.

If the mplsLdpLspFecSegment is inSegment(1), then this index has the same value as mplsInSegmentLdpLspIndex.

If the mplsLdpLspFecSegment is outSegment(2), then this index has the same value as mplsOutSegmentLdpLspIndex.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.166.4.1.3.10.1.3

mplsLdpLspFecIndex

IndexInteger

Not-accessible

This index identifies the FEC entry in the mplsFecTable associated with this session.

In other words, the value of this index is the same as the value of the mplsFecIndex that denotes the FEC associated with this Session.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.166.4.1.3.10.1.4

mplsLdpLspFecStorageType

StorageType

Read-create

The storage type for this conceptual row.

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.166.4.1.3.10.1.5

mplsLdpLspFecRowStatus

RowStatus

Read-create

The status of this conceptual row. If the value of this object is 'active(1)', then none of the writable objects of this entry can be modified.

The Agent should delete this row when the session ceases to exist. If an operator wants to associate the session with a different FEC, the recommended procedure is (as described in detail in the section entitled, 'Changing Values After Session Establishment', and again described in the DESCRIPTION clause of the mplsLdpEntityAdminStatus object) is to set the mplsLdpEntityAdminStatus to down, thereby explicitly causing a session to be torn down.

This will also cause this entry to be deleted.

Then, set the mplsLdpEntityAdminStatus to enable which enables a new session to be initiated. Once the session is initiated, an entry may be added to this table to associate the new session with a FEC.

Currently, the maximum access is read-only.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The LDP LSP must be set up on this device for an enter FEC.