MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntSipAgDmmParaTable

hwEntSipAgDmmParaTable

This table is used to configure digital map parameters.

The index of this table is hwEntSipAgId. For the definition of hwEntSipAgId, see the topic related to hwEntSipAgConfigTable.

The table entry of this table is hwEntSipAgDmmParaEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.250.7.1.1

hwEntSipAgDmmParaId

Integer32

This object indicates the ID of a SIP AG interface.

Value range: 0 to 16777215

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.250.7.1.2

hwEntSipAgDmmParaStartTimer

Integer32

This object indicates the duration of the digit map start timer.

Value range: 0 to 99

Default value: 20

Unit: second

Read-write

Current

1.3.6.1.4.1.2011.5.25.250.7.1.3

hwEntSipAgDmmParaShortTimer

Integer32

This object indicates the duration of the digit map short timer.

Value range: 1 to 99

Default value: 4

Unit: second

Read-write

Current

1.3.6.1.4.1.2011.5.25.250.7.1.4

hwEntSipAgDmmParaLongTimer

Integer32

This object indicates the duration of the digit map long timer.

Value range: 1 to 99

Default value: 20

Unit: second

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.