Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPotsLoopTestTable

hwEntPotsLoopTestTable

This table is used to configure the loop test.

The loop test is used to test electrical specifications between the device and phones. The test measures the subscriber line characteristics and compares the characteristics with various health thresholds for external lines to obtain qualitative conclusions about the external line situation.

This table does not have any indexes.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.314.2.1

hwEntPotsLoopTestOprType

INTEGER

This object indicates the operation type.

The options are as follows:

  • 1: stop
  • 2: start

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.2

hwEntPotsLoopTestPort

Integer32

This object indicates the test port number.

bits 31-24: reserved

bits 23-16: slot index

bits 15-8: subcard index

bits 7-0: port index

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.3

hwEntPotsLoopTestBusyFlag

INTEGER

This object indicates the busy test processing flag.

The options are as follows:

  • 1: cancel
  • 2: busytest
  • 3: force
  • 4: defer

The busy test is completed by the NMS. The device does not process this enumeration. That is, when a user selects the busy test, and the host returns a message indicating that the user port is busy, the NMS records the status, delays the test for a period of time, and then performs the test for the user.

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.4

hwEntPotsLoopTestTimeOut

Integer32

This object indicates the delay of the busy test.

Value range: 1 to 1440

Default value: 30

Unit: minute

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.5

hwEntPotsLoopTestTimeProc

INTEGER

This object indicates the options for handling the situation when the busy test times out.

The options are as follows:

  • 1: noTest
  • 2: mandatoryTest

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.6

hwEntPotsLoopTestVoltage [6]

INTEGER

This object indicates the voltage.

The options are as follows:

  • 1: noSelect
  • 2: select

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.7

hwEntPotsLoopTestResistance [7]

INTEGER

This object indicates the resistance.

The options are as follows:

  • 1: noSelect
  • 2: select

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.8

hwEntPotsLoopTestCapacitance

INTEGER

This object indicates the capacitance.

The options are as follows:

  • 1: noSelect
  • 2: select

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.9

hwEntPotsLoopTestLoopResistance [9]

INTEGER

This object indicates the loop resistance.

The options are as follows:

  • 1: noSelect
  • 2: select

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.10

hwEntPotsLoopTestInverseResistance [10]

INTEGER

This object indicates the polarity reversal resistance.

The options are as follows:

  • 1: noSelect
  • 2: select

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.2.11

hwEntPotsLoopTestStatus

INTEGER

This object indicates the test status.

The options are as follows:

  • 1: normal
  • 2: testFail
  • 3: portBusy
  • 4: outofTime
  • 5: testingAbnormal
  • 6: testCanceled

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.12

hwEntPotsLoopTestConclusion [12]

Integer32

This object indicates the qualitative conclusion for the external line.

Value range: 1 to 28

1: normal

2: A/B wire touching the power line

3: shorted A wire with wire of an adjacent twisted pair

4: shorted B wire with wire of an adjacent twisted pair

5: shorted A and B wires between twisted pairs

6: grounded A wire

7: grounded B wire

8: grounded A and B wires

9: self-shorted (small resistance)

10: poor insulation between A and B wires

11: A wire leakage to the ground

12: B wire leakage to the ground

13: A and B wires leakage to the ground

14: leakage between A and B wires

15: line cut (A and B wires)

16: off-hook

17: unknown

18: intra-office self-shorted

19: outer-office self-shorted

20: intra-office line cut

21: outer-office line cut

22: abnormal voltage between A and B wires

23: abnormal voltage on wires

24: abnormal resistance on wires

25: abnormal resistance between A and B wires

26: self-shorted or off-hook

27: abnormal electrical specifications

28: unknown

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.13

hwEntPotsLoopTestACAGnd

Integer32

This object indicates the A->ground AC voltage.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.14

hwEntPotsLoopTestACBGnd

Integer32

This object indicates the B->ground AC voltage.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.15

hwEntPotsLoopTestACAB

Integer32

This object indicates the A->B AC voltage.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.16

hwEntPotsLoopTestDCAGnd

Integer32

This object indicates the A->ground DC voltage.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.17

hwEntPotsLoopTestDCBGnd

Integer32

This object indicates the B->ground DC voltage.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.18

hwEntPotsLoopTestDCAB

Integer32

This object indicates the A->B DC voltage.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.19

hwEntPotsLoopTestRAGnd

Integer32

This object indicates the A->ground insulation resistance.

The value is expressed in ohms.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.20

hwEntPotsLoopTestRBGnd

Integer32

This object indicates the B->ground insulation resistance.

The value is expressed in ohms.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.21

hwEntPotsLoopTestRAB

Integer32

This object indicates the A->B insulation resistance.

The value is expressed in ohms.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.22

hwEntPotsLoopTestCAGnd

Integer32

This object indicates the A->ground capacitance.

The value is expressed in microfarads.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.23

hwEntPotsLoopTestCBGnd

Integer32

This object indicates the B->ground capacitance.

The value is expressed in microfarads.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.24

hwEntPotsLoopTestCAB

Integer32

This object indicates the A->B capacitance.

The value is expressed in microfarads.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.25

hwEntPotsLoopTestLR

Integer32

This object indicates the A->B loop resistance.

The value is expressed in ohms.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.26

hwEntPotsLoopTestRRevPole

Integer32

This object indicates the A->B polarity reversal resistance.

The value is expressed in ohms.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.2.27

hwEntPotsLoopTestMSocket [27]

INTEGER

This object indicates whether the phone is connected.

The options are as follows:

  • 1: notConnected
  • 2: connected

Read-only

Current

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 100582

Downloads: 654

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next