MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwMGTrackInterfaceTable

hwMGTrackInterfaceTable

This table describes attributes of the track interface. The information includes the index and down-weight of the track interface and the status of the association between the track interface and the interface monitoring group.

The indexes of this table are hwMGMonitorGroupIndex and hwMGTrackInterfaceIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.312.1.3.1.1

hwMGTrackInterfaceIndex

InterfaceIndex

not-accessible

This object indicates the index of the track interface. The index identifies a unique track interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.312.1.3.1.2

hwMGTrackInterfaceWeight

Integer32 (0..1000)

read-write

This object indicates the down-weight of the track interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.312.1.3.1.3

hwMGTrackInterfaceTriggerStatus

INTEGER

{

triggerup(1),

triggerdown(2),

normal(3)

}

read-only

This object indicates the status of the association between the track interface and the interface monitoring group. By default, the status is normal.
  • triggerup(1): If the track interface is triggered to go Down, and the sum of down-weights of the faulty binding interfaces in the interface monitoring group becomes less than the down-weight of the track interface, the track interface is triggered to go Up.
  • triggerdown(2): If the sum of down-weights of the faulty binding interfaces in the interface monitoring group is greater than or equal to the down-weight of the track interface, the track interface is triggered to go Down.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No association between track interfaces and the interface monitoring group can be created.

Modification Restriction

The down-weight of track interfaces can be modified. The sum of down-weights of all binding interfaces in the interface monitoring group must be greater than or equal to the maximum down-weight of track interfaces.

Deletion Restriction

The association between track interfaces and the interface monitoring group cannot be deleted.