Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTunnelCfgTable

hwTunnelCfgTable

This table is the configuration table for the IPv6 over IPv4 tunnel and IPv4 over IPv6 tunnel on a device and is composed of multiple sequential hwTunnelCfgEntry entries that describe configurations of the IPv6 over IPv4 tunnel and IPv4 over IPv6 tunnel.

The index of this table is ipv6IfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.201.1.1.1.1

hwTunnelProtocol

INTEGER { gre(1), mplsTe(2), ipv6Ipv4(3), ipv6Ipv4Auto(4), ipv6Ipv46to4(5), ipv6Ipv4Isatap(6), ipv4Ipv6(7), none(8) }

Read-write

This object indicates the tunnel protocol type. The tunnel type cannot be set to GRE (value: 1) or MPLS-TE (value: 2).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.1.1.2

hwTunnelSourceType

INTEGER { interfaceName(1), sourceAddress(2), unknown (3) }

Read-write

This object indicates the source type of a tunnel is an address or an interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.1.1.3

hwTunnelSrcIfName

DisplayString

Read-write

This object indicates the name of the source interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.1.1.4

hwTunnelAddrType

InetAddressType

Read-write

This object indicates the types of the source address and the destination address.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.1.1.5

hwTunnelSourceAddr

InetAddress

Read-write

This object indicates the source address.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.1.1.6

hwTunnelDestinationAddr

InetAddress

Read-write

This object indicates the destination address.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.1.1.7

hwTunnelCfgUndoFlag

INTEGER { undoTunnelProtocol(1), undoTunnelSource(2), undoTunnelDestination(3), invalid(4) }

Read-write

This object indicates the canceling of configurations of the tunnel protocol, source address, source interface, or destination address.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None

Modification Restriction