No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTrngPeriodicTable

hwTrngPeriodicTable

This table is used to create a periodic time range, which is a sub-time range. There are two types of sub-time ranges: periodic time ranges and absolute time ranges.

The indexes of this table are hwTrngPeriodicNameIndex and hwTrngPeriodicSubIndex.

OID

Object Name

Syntax

Description

Max Access

Implemented Specifications

1.3.6.1.4.1.2011.5.25.13.1.3.1.1

hwTrngPeriodicNameIndex

Integer32

This object indicates the primary index corresponding to the index of hwTrngCreateTimerangeTable. The value ranges from 1 to 256.

Not-accessible

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.3.1.2

hwTrngPeriodicSubIndex

Integer32

This object indicates the secondary index corresponding to the index of a periodic sub-time range. The value ranges from 1 to 32.

Not-accessible

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.3.1.3

hwTrngPeriodicDayofWeek

Integer32

This object indicates the days of a week in which the sub-time range repeats. The value ranges from 1 to 7.

Read-create

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.3.1.4

hwTimerangePeriodicStartTime

DateAndTime

This object indicates the start time.

Set this object in hexadecimal format. Use the time 06:09 as an example. Its hexadecimal format is as follows:

# 0x00 0x00 0x00 0x00 0x06 0x09 0x00 0x00

The format is 2d-1d-1d, 1d:1d:1d:1d for the Walk operation.

Read-create

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.3.1.5

hwTimerangePeriodicEndTime

DateAndTime

This object indicates the end time.

Set this object in hexadecimal format. Use the time 10:09 as an example. Its hexadecimal format is as follows:

# 0x00 0x00 0x00 0x00 0x0a 0x09 0x00 0x00

The format is 2d-1d-1d, 1d:1d:1d:1d for the Walk operation.

Read-create

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.3.1.6

hwTimerangePeriodicRowStatus

RowStatus

This object indicates the row status:

  • 4: CreateAndGo
  • 6: destroy

Read-create

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

To create a row in this table, ensure that the row corresponding to the primary index in hwTrngCreateTimerangeTable exists and the row status must be CreateAndGo.

Modification Restriction

No entry in this table can be modified.

Deletion Restriction

To delete entries in this table, specify the secondary index and row status.

Access Restriction

The entries in this table can be read when hwTrngCreateTimerangeTable can be read.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 98863

Downloads: 652

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share