Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxSIPServerConfigTable

hwEntPbxSIPServerConfigTable

This table is used to configure and maintain the SIP server.

The index of this table is hwEntPbxSIPServerIndex.

The table entry of this table is hwEntPbxSIPServerConfigEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.1

hwEntPbxSIPServerIndex

Integer32

This object indicates the index of the SIP server.

Currently, only one SIP server is supported. The index is fixed as 0.

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.2

hwEntPbxSIPServerRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.3

hwEntPbxSIPServerSignallingIP

IpAddress

This object indicates the signaling IP address.

read-create

Current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.4

hwEntPbxSIPServerSignallingPort

Integer32

This object indicates the signaling port number.

Value range: 5000 to 5999

read-create

Current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.5

hwEntPbxSIPServerMediaIP

IpAddress

This object indicates the media IP address.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.6

hwEntPbxSIPServerRegUri

OCTET STRING

This object indicates the registrar URI.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.7

hwEntPbxSIPServerHomeDomain

OCTET STRING

Indicates the home domain name.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.8

hwEntPbxSipServerSignallingDomain

OCTET STRING

This object indicates the signaling domain name.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.9

hwEntPbxSipServerDdnsClientName

OCTET STRING

This object indicates the DDNS client name for the updated DDNS domain address.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.10

hwEntPbxSipServerDynSignallingIPName

OCTET STRING

This object indicates the dynamic signaling IP name.

Length: a string of 1 to 64 characters

NOTE:

This object can be configured only after hwEntPbxSipServerDdnsClientNam and hwEntPbxSipServerSignallingDomain are configured.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.11

hwEntPbxSipServerDynMediaIPName

OCTET STRING

This object indicates the dynamic media IP name.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.12

hwEntPbxSIPServerTransfer

INTEGER

This object indicates the transmission mode.

The options are as follows:

  • 1: tcp
  • 2: udp
  • 3: sctp
  • 4: tls

Default value: udp

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.13

hwEntPbxSIPServerCSmode

INTEGER

This object indicates the client/server mode.

The options are as follows:

  • 1: server
  • 2: client_server
NOTE:

If hwEntPbxSIPServerTransfer is set to udp, the configuration of this object does not take effect. If hwEntPbxTrkGrpTransfer is set to tcp or tls, this object must be configured.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.14

hwEntPbxSIPServerSignallingProxy

INTEGER

This object indicates the signaling proxy policy.

The options are as follows:

  • 1: disable
  • 2: enable
  • 3: auto

Default value: disable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.15

hwEntPbxSIPServerMediaProxy

INTEGER

This object indicates the media proxy policy.

The options are as follows:

  • 1: disable
  • 2: enable
  • 3: auto

Default value: disable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.16

hwEntPbxSIPServerMappedSignallingIP

IpAddress

This object indicates the mapped public signaling IP address.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.17

hwEntPbxSIPServerMappedSignallingPort

Integer32

This object indicates the mapped public signaling port number.

Value range: 1 to 65535

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.18

hwEntPbxSIPServerMappedMediaIP

IpAddress

This object indicates the mapped public media IP address.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.19

hwEntPbxSIPServerMappedMediaPortStart

Integer32

This object indicates the mapped start media port number.

Value range: 1 to 65535

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.20

hwEntPbxSIPServerMappedMediaProxyPortStart

Integer32

This object indicates the mapped start media proxy port number.

Value range: 1 to 65535

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.21

hwEntPbxSIPServerAdminStatus

INTEGER

This object indicates the management operation.

The options are as follows:

  • 1: reset
  • 2: shutdown

read-write

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.22

hwEntPbxSIPServerMediaBandwidthControlSwitch

INTEGER

This object indicates whether to enable conventional media bandwidth control on the SIP server.

The values are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.23

hwEntPbxSIPServerMaxBandwidth

Integer32

This object indicates the maximum conventional media bandwidth on the SIP server, in 100 kbit/s.

The value ranges from 1 to 5000.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.24

hwEntPbxSIPServerMediaProxyMediaBandwidthControlSwitch

INTEGER

This object indicates whether to enable media bandwidth control when the SIP server serves as the media proxy.

The values are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.8.1.25

hwEntPbxSIPServerMediaProxyMaxBandwidth

Integer32

This object indicates the maximum media bandwidth when the SIP server serves as the media proxy, in 100 kbit/s.

The value ranges from 1 to 5000.

read-create

current

Creation Restriction

  1. Only one SIP server is supported. The index is 0.
  2. To create an entry, set values for the following objects: hwEntPbxSIPServerSignallingIP (or hwEntPbxSipServerDynSignallingIPName), hwEntPbxSIPServerSignallingPort, hwEntPbxSIPServerMediaIP (or hwEntPbxSipServerDynMediaIPName), hwEntPbxSIPServerRegUri, and hwEntPbxSIPServerHomeDomain.

Modification Restriction

None.

Deletion Restriction

  1. The entries in this table cannot be deleted when the SIP server is being reset.
  2. The entries in this table cannot be deleted if SIP terminal users are configured on the SIP server.
  3. The entries in this table cannot be deleted if services configured on the SIP server are associated with other tables. In such a case, the entries can be deleted only after you de-associate services from other tables.

Access Restriction

None.