Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwMstpDiameter

hwMstpDiameter

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.42.4.1.3

hwMstpDiameter

INTEGER(2..7)

Read-write

The value of this object identifies the network diameter of the SPT.

It affects the time that includes hello time, forward delay time and maxage.

Every bridge can set the diameter of Bridge, and it is effective when the bridge is the root bridge. Effective in the CIST.

The value ranges from 2 to 7. The default value is 7.

This object is implemented as defined in the corresponding MIB files.