No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwSvcTable

hwSvcTable

This table is an SVC configuration table. You can create and delete an SVC by using the table. Now the entries in this table can be queried only.

The index of this table is hwSvcIfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.1

hwSvcIfIndex

InterfaceIndexOrZero

Not-accessible

This object indicates the index of the AC interface associated with the SVC.

The value 0 indicates that the index of the interface is invalid.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.2

hwSvcID

Unsigned32(0~4294967295)

Read-create

This object indicates the VC ID.

The value is a decimal integer that ranges from 0 to 4294967295.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.3

hwSvcType

HWL2VpnVcEncapsType

Read-create

This object indicates the encapsulation type of the PW.

For details, see hwPwVcType.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.4

hwSvcPeerAddrType

InetAddressType

Read-create

The value of this object identifies the type of the peer IP address.

  • 0: unknown address
  • 1: IPv4 address
  • 2: IPv6 address
  • 3: IPV4z address
  • 4: IPV6z address
  • 16: DNS

Currently, the maximum access is read-only;

At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.5

hwSvcPeerAddr

IpAddress

Read-create

This object indicates the peer IP address of the SVC.

If the type of hwSvcPeerAddrType is unknown, the peer IP address of the SVC is all 0s.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.6

hwSvcStatus

Integer{up(1),down(2),plugout(3)}

Read-only

The value of this object identifies the SVC status of the local node.

  • 1: Up
  • 2: Down
  • 3: Plugout

At present, this object does not support the plugout status.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.7

hwSvcInboundLabel

Unsigned32

Read-create

This object indicates the value of the inbound label for the SVC.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.8

hwSvcOutboundLabel

Unsigned32

Read-create

This object indicates the value of the outbound label for the SVC.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.9

hwSvcGroupID

Unsigned32

read-only

This object indicates the SVC ID.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.10

hwSvcAcStatus

Integer{up(1),down(2),plugout(3)}

Read-only

The value of this object identifies the physical status of the AC.

  • 1: Up
  • 2: Down
  • 3: Plugout

At present, this object does not support the plugout status.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.13

hwSvcCtrlWord

HWEnableValue

Read-create

The value of this object identifies the capability of control word.

  • 1: enable
  • 2: disable

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.14

hwSvcVCCV

BITS { ccCw(0), ccAlert(1), ccLabel(2), cvIcmpping(3), cvLspping(4), cvBfd(5) }

Read-create

Indicates the optional VCCV capabilities of the SVC.

The default value is ccAlert(1), cvLspping(4), and cvBfd(5).

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.17

hwSvcTnlPolicyName

Octet String(size(0..39))

Read-create

This object indicates the name of the tunnel policy. The name is a string of 1 to 19 characters.

By default, the length of the name is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.19

hwSvcPWTemplateName

Octet String(size(0..19))

Read-create

This object indicates the name of the PW template. The name is a case-sensitive string of 0 to 19 characters. If not specified, the default value of the object is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.20

hwSvcUpTime

Unsigned32

Read-only

This object indicates the duration when the SVC keeps Up for the last time, in seconds.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.23

hwSvcSecondary

TruthValue

read-create

This object indicates whether or not the secondary PW is used.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.30

hwSvcActive

TruthValue

read-only

This object indicates the state of am SVC.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.31

hwSvcUpStartTime

DisplayString (SIZE (0..63))

Read-only

This object indicates the time when the PW returns to the Up state last time.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.32

hwSvcUpSumTime

Unsigned32

Read-only

This object indicates the accumulated time when the SVC is Up, in seconds.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.34

hwSvcPwJitterBufferDepth

Unsigned32 (0..64)

Read-create

This object indicates the depth of the jitter buffer. The value is a decimal integer that ranges from 0 to 64, in ms. By default, the depth is 20 ms. If the value is set to 0, the default depth is used.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.35

hwSvcPwTdmEncapsulationNum

Unsigned32 (0..40)

Read-create

This object indicates the number of frames in a TDM packet. The value is a decimal integer that ranges from 0 to 40. The default value is 32. If the value is set to 0, the default depth is used.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.36

hwSvcPwIdleCode

Unsigned32 (0..255 | 65535)

Read-create

This object indicates the value of an idle code. The value is a hexadecimal number ranging from 0x00 to 0xFF. The default value is 0xFF and the invalid value is 0xFFFF.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.38

hwSvcRawOrTagged

INTEGER { raw(1), tagged(2), rawTagNotConfiged(3) }

Read-create

Specifies whether the VLAN tag of the SVC entry is attached or stripped.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.3.1.1.51

hwSvcRowStatus

RowStatus

Read-create

This object indicates the row status of this table.

Restriction:

  • To create this table, you must adopt the CreatAndGo processing mode, rather than the CreatAndWait processing mode.
  • After creating this table, you are unable to modify the configuration.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None

Modification Restriction

None

Deletion Restriction

None

Access Restriction

None

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 121616

Downloads: 683

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share