MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwRadioRegionCalibrateTable(for AC)

hwRadioRegionCalibrateTable(for AC)

This table describes the radio calibration information.

The index of this table is hwApRegionIndex.

OID

Object Name

Syntax

Description

Access

Status

1.3.6.1.4.1.2011.6.139.3.10.1.1

hwRegionCalibrateStartupMode

INTEGER

This object indicates the global calibration mode:

1: immediate(1)

2: periodic(2)

3: cancel-periodic(3)

Read-write

Current

1.3.6.1.4.1.2011.6.139.3.10.1.2

hwRegionCalibrateAutoTime

DateAndTime

This object indicates the time when global radio calibration will start every day.

Read-write

Current

1.3.6.1.4.1.2011.6.139.3.10.1.3

hwRegionCalibrateListenMode

INTEGER

This object indicates whether the neighboring information is kept during the global calibration.

1: enable(1)

2: disable(2)

Read-write

Current

1.3.6.1.4.1.2011.6.139.3.10.1.4

hwRegionCalibrateStatus

INTEGER

This object indicates the status of global calibration:

1: running(1): indicates that the global calibration is being performed.

2: stop(2): indicates that the global calibration finishes.

Read-only

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

No entry in this table can be deleted.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 121609

Downloads: 683

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next