MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxUsrGrpTable

hwEntPbxUsrGrpTable

This table is used to configure and maintain user groups.

The index of this table is hwEntPbxUsrGrpName.

The table entry of this table is hwEntPbxUsrGrpEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.1

hwEntPbxUsrGrpName

OCTET STRING

This object indicates a user group name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.2

hwEntPbxUsrGrpRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.3

hwEntPbxUserGroupServiceId

INTEGER

This object indicates the service type.

The options are as follows:

  • 1: ivr
  • 2: ringParallel
  • 3: ringSerial
  • 4: unicall
  • 5: pickup
  • 6: hunt
  • 7: navi

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.4

hwEntPbxUsrGrpEnterpriseName

OCTET STRING

This object indicates an enterprise name.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.5

hwEntPbxUsrGrpDnSet

OCTET STRING

This object indicates the DN set.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.6

hwEntPbxUserGroupCentrex

OCTET STRING

This object indicates the Centrex group name.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.7

hwEntPbxUsrGrpCountryCode

OCTET STRING

This object indicates the country or region code.

Length: a string of 1 to 4 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.8

hwEntPbxUsrGrpAreaCode

OCTET STRING

This object indicates the area code.

Length: a string of 1 to 8 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.9

hwEntPbxUserGrpAccessCode

OCTET STRING

This object indicates the access number.

Length: a string of 1 to 24 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.10

hwEntPbxUserGrpRegCode

OCTET STRING

This object indicates the registered number (the number is only used in ONLY service).

Length: a string of 1 to 24 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.11

hwEntPbxUserGrpConsoleCode

OCTET STRING

This object indicates the switchboard number.

Length: a string of 1 to 24 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.12

hwEntPbxUsrGrpDstEnterprise

OCTET STRING

This object indicates the destination enterprise name.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.13

hwEntPbxUserGrpDstDnset

OCTET STRING

This object indicates the destination DN set.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.14

hwEntPbxUserGrpDstCentrex

OCTET STRING

This object indicates the destination Centrex group name.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.15

hwEntPbxUserGrpMaxQueueNum

Integer32

This object indicates the maximum number of concurrent calls.

Value range: 0 to 65535

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.16

hwEntPbxUserGrpToneId

Integer32

This object indicates the tone ID.

The options are as follows:

1: busy tone

2: howler tone

3: dial tone

4: ringing tone

5: two-stage dial tone

6: special dial tone

7: short busy tone

8: call waiting tone

9: mute tone

10: CAS tone

11: SAS tone

12: MWI-on

13: MWI-off

14: confirmation tone

15: call blocking tone

16: reject tone

17: self-defined voice 1

18: self-defined voice 2

19: self-defined voice 3

20: self-defined voice 4

21: self-defined voice 5

22: reserved

23: reserved

24: message leaving tone

25: call waiting tone 2

26: number-unobtainable tone

27: system busy tone

28: number-unidentified tone

29: fault

30: temporary disorder of numbers

31: no response

32: The line is busy.

33: invalid number

34: delete participants

35: Call sessions cannot be set up.

36: calling time

37: reject the called number

38: no dial-up

39: service termination

40: the first part of the RO tone

41: the second part of the RO tone

42: PCCW call waiting tone 3:0.1s on/0.1s off/0.1s on (2 times)

43: PCCW call waiting tone 4:1s on/1s off/1s on (1 time)

44: PCCW call waiting tone 5:0.5s on/0.5s off (1 time)

45: PCCW signal tone: stutter dial tone (STT)

46: PCCW signal tone: congestion tone (CT)

47: PCCW signal tone: number unobtainable tone (NUT)

48: PCCW signal tone: service acceptance tone (SAT) or confirmation tone

49: MGC overload tone

50: Bulgaria locking line tone

51: Argentina message leaving tone

52: call holding tone

53: confirmation tone

54: All lines are busy.

55: alarm tone

56: special message tone

57: The number is being located. 58: call waiting tone

59: call barring tone when the power consumption exceeds the threshold

60: play 2100 Hz signal tone on local device for modem if interconnection test fails.

61: 0

62: 1

63: 2

64: 3

65: 4

66: 5

67: 6

68: 7

69: 8

70: 9

71: Monday

72: Tuesday

73: Wednesday

74: Thursday

75: Friday

76: Saturday

77: Sunday

78: year

79: month

80: day

81: Thanks for calling Huawei company. Please dial the extension number.

82-90: reserved

91: The service you applied has been registered. Welcome to use this service.

92: You have applied for other services. This application failed.

93: Your service has been canceled. Thank you.

94: Service cancellation failed.

95: queue/third party/meeting hold tone

96: The subscriber you dialed has enabled the DND service.

97: The subscriber you dialed has enabled the RAC service.

98: Connecting, hold on please

99: waiting tone <The subscriber you dialed is busy now, please redial later.>

100: Sorry, you have no rights.

101: Please dial xxx for the switchboard number.

102: Your number is xxx.

103: Thank you for calling.

104: You have enabled the call forward service. The forwarded-to number is xxx.

105: incorrect number tone <The number you dialed is incorrect.>

106: The called user is busy <Sorry, the number you dialed is busy now, please try later.>

107: called number fault tone <Sorry, the subscriber you dialed cannot be connected, please redial later.>

108: The called number cannot be connected <Sorry, the number you dialed cannot be connected, please try later.>

109: call barring <You have no rights to call this number.>

110: called number absent <The subscriber you dialed has enabled the absent user service, please redial later.>

111: wakeup tone <The set time is up.>

112: forward restriction <Sorry, the call forward failed.>

113: The service you registered is activated.

114: The service you registered cannot be activated. Please try again. Thank you.

115: Ten

116: activated

117: inactivated

118: The service you registered is deactivated.

119: The service you registered cannot be deactivated. Please try again. Thank you.

120: File query failed. Please try again.

121: daily

122: weekly

123: accept

124: reject

125: to

126: call

127: *

128: dot

129: minute

130: X or x

131: The subscriber you dialed is busy now. Please try later.

132: The phone you dialed is not answered for the moment, please redial later.

133: The subscriber you dialed is not in service.

134: The number you dialed does not exist. Please check it and dial later.

135: You have no rights to use this service.

136: The subscriber you dialed cannot be connected. Please try later.

137-153: The subscriber can customize announcements (reserved).

154: mute

155: The service password you entered is incorrect. Please check and enter the correct password.

156: You have changed your password.

157: The new password you entered is incorrect. Please enter the correct one.

158: You have applied for the remote office service. The remote office service number is xxx.

159: You have applied for the secretary service. The secretary service number is xxx.

Default value: 81

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.17

hwEntPbxUsrGrpToneFileName

OCTET STRING

This object indicates the name of the announcement file.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.18

hwEntPbxUserGrpQueue

INTEGER

This object indicates whether to enable the queuing sequence.

The options are as follows:

  • 1: disable
  • 2: enable

Default value: disable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.19

hwEntPbxUserGrpQueueTime

Integer32

This object indicates the queuing duration.

Value range: 0 to 3600

Unit: second

Default value: 180

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.20

hwEntPbxUserGrpRingMode

INTEGER

This object indicates the ringing mode.

The options are as follows:

  • 1: ringParallel
  • 2: ringSerial
  • 3: ringOne

Default value: ringParallel

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.21

hwEntPbxUserGrpSelectmode

INTEGER

This object indicates the line selection mode.

The options are as follows:

  • 1: loop
  • 2: increase
  • 3: decrease

Default value: loop

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.22

hwEntPbxUserGrpRingTime

Integer32

This object indicates the ringing duration.

Value range: 1 to 255

Unit: second

Default value: 10

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.23

hwEntPbxUsrGrpIvrNaviMenuName

OCTET STRING

This object indicates the name of a navigation menu.

Length: a string of 1 to 32 characters

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.24

hwEntPbxUsrGrpDirectTransConsole

INTEGER

This object indicates whether to directly connect to the switchboard.

The options are as follows:

  • 1: disable
  • 2: enable

Default value: disable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.25

hwEntPbxUsrGrpMenuName

OCTET STRING

This object indicates the name of the current menu.

Length: a string of 1 to 32 characters

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.26

hwEntPbxUsrGrpMenuOprCode

Integer32

This object indicates the menu operation code.

The options are as follows:

0: Dial 0

1: Dial 1

2: Dial 2

3: Dial 3

4: Dial 4

5: Dial 5

6: Dial 6

7: Dial 7

8: Dial 8

9: Dial 9

10 to 109: reserved

110: Dial *

111: Dial #

112: Dial initial number

113: Dial number ending with #

114: Timeout and there is no input

115: Matching fails

116: Maximum count of errors

117: Locating the collected information fails

118: The action fails

119: Playing voice ends

120: The calling party cancels the call

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.27

hwEntPbxUsrGrpCallerNum

OCTET STRING

This object indicates the calling number.

Length: a string of 1 to 44 digits

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.28

hwEntPbxUsrGrpFromDate

OCTET STRING

This object indicates the start date.

Length: a string of 0 to 10 characters

Format: yyyy-mm-dd

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.29

hwEntPbxUsrGrpFromTime

OCTET STRING

This object indicates the start time.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.30

hwEntPbxUsrGrpToDate

OCTET STRING

This object indicates the end date.

Length: a string of 0 to 10 characters

Format: yyyy-mm-dd

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.31

hwEntPbxUsrGrpToTime

OCTET STRING

This object indicates the end time.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.32

hwEntPbxUsrGrpRepeatMode

INTEGER

This object indicates the repeat mode.

The options are as follows:

  • 1: noRepeat
  • 2: yearly
  • 3: monthly
  • 4: weekly
  • 5: daily
NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.33

hwEntPbxUsrGrpBeginDate

OCTET STRING

This object indicates the start date of the validity cycle.

Length: a string of 0 to 5 characters

Format: mm-dd

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.34

hwEntPbxUsrGrpBeginWeekday

INTEGER

This object indicates the start weekday of the validity cycle.

The options are as follows:

  • 1: mon
  • 2: tue
  • 3: wed
  • 4: thu
  • 5: fri
  • 6: sat
  • 7: sun
  • 8: none
NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.35

hwEntPbxUsrGrpBeginTime

OCTET STRING

This object indicates the start time of the validity cycle.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.36

hwEntPbxUsrGrpEndDate

OCTET STRING

This object indicates the end date of the validity cycle.

Length: a string of 0 to 5 characters

Format: mm-dd

NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.37

hwEntPbxUsrGrpEndWeekday

INTEGER

This object indicates the end weekday of the validity cycle.

The options are as follows:

  • 1: mon
  • 2: tue
  • 3: wed
  • 4: thu
  • 5: fri
  • 6: sat
  • 7: sun
  • 8: none
NOTE:

This object is not supported temporarily.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.19.1.38

hwEntPbxUsrGrpEndTime

OCTET STRING

This object indicates the end time of the validity cycle.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

NOTE:

This object is not supported temporarily.

read-create

current

Creation Restriction

To create an entry, set values for hwEntPbxUserGroupServiceId and hwEntPbxUsrGrpEnterpriseName.

Modification Restriction

None.

Deletion Restriction

The entries cannot be deleted if a user configured in a user group is associated with other tables. To delete the user group, delete the user associated with other tables.