No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

AR500, AR510, and AR530 V200R007 CLI-based Configuration Guide - Ethernet Switching

This document describes the configuration of Ethernet services, including configuring transparent bridge, MAC table, link aggregation, VLANs, STP/RSTP/MSTP, and so on.The document provides the configuration procedures and configuration examples to illustrate the service configuration methods and application scenario.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
A VLANIF Interface Fails to Be Created

A VLANIF Interface Fails to Be Created

Fault Symptom

When a user attempts to create a VLANIF interface, the system displays an error message. As a result, the VLANIF interface fails to be created.

Procedure

  1. Check the error message during VLANIF interface creation.

    Rectify the fault according to the error message. See Table 3-5.

    Table 3-5  Fault rectification according to the error message

    Message

    Cause Analysis and Check Method

    Solution

    Error: The VLAN does not exist.

    The VLAN is not created on the device.

    Run the display vlan summary command to check whether the value of the static vlan field is the VLAN corresponding to the VLANIF interface.

    Run the vlan vlan-id command to create a VLAN corresponding to the VLANIF interface and then create a VLANIF interface.

    Error: The VLAN is used by XXX.

    NOTE:

    XXX indicates a feature, such as SEP, or GVRP.

    The VLAN corresponding to the VLANIF interfaces is a dynamic, control, or reserved VLAN.

    Run the display vlan summary command to check whether the value of the dynamic vlan or reserved vlan field is the VLAN corresponding to the VLANIF interface.

    Create a VLANIF interface corresponding to another VLAN.

  2. If the fault persists, collect alarms and logs and contact Huawei technical support personnel.