Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
display temperature

display temperature

Function

The display temperature command displays temperature information on a PoE midspan.

Format

display temperature

Parameters

None

Usage Guidelines

A PoE midspan can operate stably at a proper temperature and may be corrupted at a high or low temperature. You can run this command to check the current temperature of the PoE midspan. When the temperature exceeds the upper or lower threshold, the PoE midspan generates an alarm, indicating that the PoE midspan is not working normally.

Example

# Display temperature information on a PoE midspan.

[Huawei] display temperature
-------------------------------                                                 
Status   Upper  Lower  Temp(C)                                                  
-------------------------------                                                 
NORMAL    85      -40     39 
Table 3-65  Description of the display temperature command output

Item

Description

Status

Temperature status:
  • NORMAL: The temperature is within the normal range.
  • MINOR: The temperature is out of the allowed range.
  • ABNORMAL: The temperature is out of the normal range.