No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Command Reference

AR500, AR510, and AR530 V200R007

This document describes all the configuration commands of the device, including the command function, syntax, parameters, views, default level, usage guidelines, examples, and related commands.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
display poe chip debug information

display poe chip debug information

Function

The display poe chip debug information command displays PoE chip debugging information.

Format

display poe chip debug information

Parameters

None

Usage Guidelines

You can use this command to check the device initialization status and information such as the device chip, ports, and output power when the device is running.

Example

# Display PoE chip running information.

[Huawei] display poe chip debug information
Port Detect               Class           PowerSupply                                                                               
 0   Open circuit         Unknown         Abnormal                                                                                  
 1   Open circuit         Unknown         Abnormal                                                                                  
 2   Open circuit         Unknown         Abnormal                                                                                  
 3   Open circuit         Unknown         Abnormal                                                                                  
 4   Open circuit         Unknown         Abnormal                                                                                  
 5   Open circuit         Unknown         Abnormal                                                                                  
 6   Open circuit         Unknown         Abnormal                                                                                  
 7   Open circuit         Unknown         Abnormal    
Table 3-61  Description of the display poe chip debug information command output

Item

Description

Port

Port number.

Detect

Detection result on the port:
  • Unknown: The state is unknown.
  • Short circuit: A short-circuit condition occurs.
  • Reserved: The port is a reserved port.
  • Resistance too low: The resistance is too low.
  • Resistance too high: The resistance is too high.
  • Open circuit: An open-circuited condition has occurred.
  • MOSFET fault: A MOSFET fault has occurred.
  • Legacy detect: The port is detecting PD compatibility.
  • Capacitance invalid: The capacitance is invalid.
  • Capacitance valid: The capacitance is valid.

Class

Class of the PD connected to the port:
  • Unknown: The state is unknown.
  • Reserved: The port is a reserved port.
  • Overcurrent: An overcurrent condition has occurred.
  • mismatch: The PD does not match the port.
  • 0: The reference power is 15.4 W.
  • 1: The reference power is 4 W.
  • 2: The reference power is 7 W.
  • 3: The reference power is 15.4 W.
  • 4: The reference power is 30 W.

PowerSupply

PoE power supply status.

Translation
Download
Updated: 2019-02-18