Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
display default-parameter interface

display default-parameter interface

Function

The display default-parameter interface command displays the default interface configuration.

Format

display default-parameter interface interface-type interface-number

Parameters

Parameter Description Value
interface-type interface-number Displays the default configuration of a specified interface. -

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

Default configurations are not saved in the configuration file. To check the default configuration of an interface, run the display default-parameter interface command on the interface.

The displayed information varies according to interfaces.

Example

# Display the default configuration of GE1/0/0.1.

<Huawei> display default-parameter interface gigabitethernet 1/0/0.1
 Interface state: undo shutdown
 MTU: 1500
 Flow-stat interval: 300s
 Trap-threshold: input-rate 100, output-rate 100
 Snmp trap updown: enable
 Description: HUAWEI, AR Series, GigabitEthernet1/0/0.1 Interface
Table 4-1  Description of the display default-parameter interface gigabitethernet command output

Item

Description

Interface state:

Default status of an interface:

  • shutdown
  • undo shutdown

To change the interface status, run the shutdown command or the undo shutdown command in the interface view.

MTU:

Default MTU value of the interface.

To set the MTU value for an interface, run the mtu command in the interface view.

Flow-stat interval:

Interval for collecting traffic statistics on the interface.

To set the interval for collecting traffic statistics on an interface, run the set flow-stat interval command in the interface view.

Trap-threshold:

Alarm threshold for outbound and inbound bandwidth usage on the interface.

To set the alarm threshold for outbound and inbound bandwidth usage on an interface, run the trap-threshold command in the interface view.

Snmp trap updown:

Whether an alarm is sent to the NMS when the interface status changes:

  • disable: No alarm is sent to the NMS when the interface status changes.
  • enable: An alarm is sent to the NMS when the interface status changes.

Description:

Interface description.

To configure the description for an interface, run the description (interface view) command in the interface view.

# Display the default configuration of Dialer1.

<Huawei> display default-parameter interface dialer 1
 MTU: 1500
 Timer hold: 10s
 Flow-stat interval: 300s
 Description: HUAWEI, AR Series, Dialer1 Interface
Table 4-2  Description of the display default-parameter interface dialer command output

Item

Description

MTU:

Default MTU value of the interface.

To set the MTU value for an interface, run the mtu command in the interface view.

Timer hold:

Polling interval of the link layer protocol applied to the interface.

To set the polling interval for an interface, run the timer hold command in the interface view.

Flow-stat interval:

Interval for collecting traffic statistics on the interface.

To set the interval for collecting traffic statistics on an interface, run the set flow-stat interval command in the interface view.

Description:

Interface description.

To configure the description for an interface, run the description (interface view) command in the interface view.