AR500, AR510, and AR530 V200R007 Commands Reference

This document describes all the configuration commands of the device, including the command function, syntax, parameters, views, default level, usage guidelines, examples, and related commands.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
poe { power-off | power-on } port

poe { power-off | power-on } port

Function

The poe { power-off | power-on } port command manually powers on or off the PD connected to a specified port.

Format

poe { power-off | power-on } port port-num

Parameters

Parameter

Description

Value

port-num

Specifies the port number of a PoE midspan. The value is an integer that ranges from 0 to 7.

Usage Guidelines

Usage Scenario

In manual power supply mode, you need to run the poe { power-off | power-on } port command to power on or off the PD connected to a specified PD. You can run the display poe power-state port command to check whether the operation succeeds.

Precautions

When a PoE midspan cannot provide sufficient power, it cannot provide power to newly connected PDs, and the poe power-on port command does not take effect.

Prerequisites

Before powering on or off a port, ensure that:

  • The power supply mode has been set to manual using the poe power-management command.

  • A PD has been connected to the port.

  • The PoE function has been enabled on the port.

  • The PD connected to the port has been detected and classified and can be powered on.

Example

# Power on the PD connected to port 0 manually.
[Huawei] poe power-management manual
[Huawei] poe power-on port 0