Log Reference

AR500, AR510, and AR530 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EFM/3/THRESHOLD

EFM/3/THRESHOLD

Message

EFM/3/THRESHOLD:Threshold-crossing event occurred. (InterfaceName=[STRING], EventLogIndex=[GAUGE], EventLogTimestamp=[TIMETICK], EventLogOui=[OPAQUE], EventLogType=[GAUGE], EventLogLocation=[INTEGER], EventLogWindowHi=[GAUGE], EventLogWindowLo=[GAUGE], EventLogThresholdHi=[GAUGE], EventLogThresholdLo=[GAUGE], EventLogValue=[COUNTER64], EventLogRunningTotal=[COUNTER64], EventLogEventTotal=[GAUGE])

Description

The threshold-crossing event occurred on the EOAM 3AH module.

Parameters

Parameter Name Parameter Meaning
InterfaceName Indicates the name of an interface.
EventLogIndex Indicates the index of an event.
EventLogTimestamp Indicates the time when the event occurs.
EventLogOui Indicates the unique identifier of a manufacturer.
EventLogType Indicates the log type.
EventLogLocation Indicates the location (1 indicates local end, 2 indicates peer end) of the event.
EventLogWindowHi Indicates the higher 4-byte interval.
EventLogWindowLo Indicates the lower 4-byte interval.
EventLogThresholdHi Indicates the higher 4-byte threshold.
EventLogThresholdLo Indicates the lower 4-byte threshold.
EventLogValue Indicates the number of errors within the interval (error frames or error codes).
EventLogRunningTotal Indicates the total number of errors after OAM is reset.
EventLogEventTotal Indicates the total number of threshold-crossing events after OAM is reset.

Possible Causes

The events of error frames, error frame seconds, and error codes were detected. The number of link faults reached the set threshold within the set interval.

Procedure

  1. Check the link and the environment, and analyze the cause of excessive error frames and error codes.