Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA/4/RISING_ALARM

NQA/4/RISING_ALARM

Message

NQA/4/RISING_ALARM:The [alarm-node] defined in nqa alarm table(OwnerIndex=[OCTET] TestName=[OCTET] AlarmEntryNumber=[INTEGER])has alarm value [alarm-value],going out of threshold [threshold].It's alarm sample type is [alarm-sample-type].

Description

The value of the monitored node was over the upper limit.

Parameters

Parameter Name Parameter Meaning
[alarm-node] Indicates the node that generates the alarm.
OwnerIndex Indicates the administrator of the NQA test instance.
TestName Indicates the name of the NQA test instance.
AlarmEntryNumber Indicates the index of the alarm table.
[alarm-value] Indicates the value of the node that generates the alarm.
[threshold] Indicates the user-defined upper limit.
[alarm-sample-type] Indicates the type of the sampled alarm.

Possible Causes

The value of the monitored node was over the upper limit.

Procedure

  1. Run the display nqa-agent command and check alarm entry-number jitter-average absolute rising-threshold to see whether the threshold value is proper.
    1. If the upper limit is too small, run the alarm command to set the upper limit to be a proper value, and then go to 3.
    2. If the upper limit is proper, go to 2.
  2. If the alarm is generated because of a network problem, check the configurations and services of the network, and contact technical support personnel.
  3. End.