Log Reference

AR500, AR510, and AR530 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS/4/ADD_SRLGTOLINK_FAIL

ISIS/4/ADD_SRLGTOLINK_FAIL

Message

ISIS/4/ADD_SRLGTOLINK_FAIL:ISIS [process-id] failed to add SRLG information to TE link. (NewSrlgNum=[USHORT], CurrentSrlgNum=[USHORT], NeighborSystemId=[STRING], NeighborPseudoNodeId=[USHORT], FragmentNumber=[USHORT])

Description

IS-IS failed to add the SRLG information to a TE link.

Parameters

Parameter Name Parameter Meaning

[process-id]

Indicates the ID of an IS-IS process.

NewSrlgNum

Indicates the number of new SRLGs.

CurrentSrlgNum

Indicates the number of SRLGs on the current link.

NeighborSystemId

Indicates the system ID of a neighbor.

NeighborPseudoNodeId

Indicates the pseudo node ID of a neighbor.

FragmentNumber

Indicates the number of the LSP fragment.

Possible Causes

1. No SRLG is added.

2. Failed to apply memory for the key data structure when adding the SRLG information.

3. The internal logic was incorrect.

Procedure

  1. Run the debugging isis receiving-packet-regular-content command and the debugging isis update-packet command, and then analyze the received packet according to the packet type and the system ID; check whether the packet does not carry an SRLG.
  2. If the TLV type is normal, perform the following:

    • Run the display memory-usage command in the user view to check whether the system memory usage is too high. If so, analyze the cause.

    • If the memory usage is normal, contact technical support personnel.

  3. If abnormality occurs in the TLV, check whether the industrial switch router sending the LSP is faulty.
  4. If the router is faulty, contact technical support personnel.
  5. End.