Log Reference

AR500, AR510, and AR530 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MSDP/4/CHECK_SOCKET_FAIL

MSDP/4/CHECK_SOCKET_FAIL

Message

MSDP/4/CHECK_SOCKET_FAIL:In VPN instance "[vpn-instance-name]", failed to handle msdp socket. The socket ID was [socket-id], the peer was [peer-address], the operation code was [operation-code], the error code was [error-code].(FlCode=[STRING][ULONG])

Description

The backup MSDP socket information is incorrect or the configurations on the standby main board are incorrect.

Parameters

Parameter Name Parameter Meaning
[vpn-instance-name]

Name of a VPN instance

[socket-id]

Socket ID

[peer-address]

Peer address

[operation-code]
Operation code
  • 1: The standby main board checks the socket.

  • 2: The standby main board obtains the local port number and address information.

  • 3: The standby main board obtains the remote port number and address information.

  • 4: The MD5 option is set.

  • 5: The KeyChain option is set.

  • 6: The standby main board checks the boundary of the received packet.

  • 7: Attributes for socket backing up are set.

  • 8: The application-ready option is set.

  • 9: Asynchronization attributes are set.

[error-code]

Error code

FlCode

Name of the source code file and the line number of this log message

Possible Causes

The set socket option was incorrect.

Procedure

  • This log message is informational only, and no action is required.