Log Reference

AR500, AR510, and AR530 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BGP/3/L2V_MAX_LB_REACHED

BGP/3/L2V_MAX_LB_REACHED

Message

BGP/3/L2V_MAX_LB_REACHED:The number of label blocks has reached the upper limit [ULONG].

Description

The label information group was full.

Parameters

Parameter Name Parameter Meaning
[ULONG] Indicates the size of the label space.

Possible Causes

The label space was exhausted.

Procedure

  1. Check the topology and the configuration of the network, and check whether the exhaustion of labels is caused by the requirements of actual applications or incorrect topology configuration.
  2. If the exhaustion of labels is caused by the requirements of actual applications, expand the device.