Log Reference

AR500, AR510, and AR530 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OPSA/3/OPS_CONTEXT_SAVE_EXECUTE_FAIL

OPSA/3/OPS_CONTEXT_SAVE_EXECUTE_FAIL

Message

OPSA/3/OPS_CONTEXT_SAVE_EXECUTE_FAIL: Script is [script-name], current event is [event-name], instance is [instance-id], fails to save script variable [varName].

Description

Failed to save the script variable to the context in the execution phase.

Parameters

Parameter Name Parameter Meaning
[script-name] Indicates a user script name.
[event-name] Indicates an event name.
[instance-id] Indicates an instance ID.
[varName] Indicates a variable name.

Possible Causes

Failed to save the script variable to the context in the execution phase.

Procedure

  1. In the execution phase of the user script, the parameter of the API saving the context (ops.context.save) is invalid or the number of saved contexts has reached the limit. You need to modify the script.