Log Reference

AR500, AR510, and AR530 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MSTP/3/PACKET_ERR_COMPLIAN

MSTP/3/PACKET_ERR_COMPLIAN

Message

MSTP/3/PACKET_ERR_COMPLIAN:The port compliance protocol type of the packet received by MSTP from the port [port-name] is invalid.

Description

The MSTP port received a BPDU with an unknown format.

Parameters

Parameter Name Parameter Meaning
[port-name] indicates the name of a port.

Possible Causes

The MSTP module received an invalid BPDU. This BPDU might be an attack BPDU or a BPDU with the private MSTP format of a non-Huawei device.

Procedure

  1. Use a tool to get the received invalid BPDU.
  2. Query and record the information about the remote end, including the manufacturer, version, and configuration.

    • If a Huawei device is used, run the display version and display interface commands or the display current-configuration command.
    • If a non-Huawei device is used, run the related commands provided by the manufacturer to obtain information on the device.

  3. If the packet received by MSTP was invalid and hence the STP status was wrong, loops may occur at Layer 2. You are advised to shut down the interface to prevent broadcast storms. To view STP status and check whether loops occur, run the display stp brief command. After confirming that loops are removed, run the undo shutdown command to enable the interface.
  4. Report the statistics on error packets and contact technical support personnel for further analysis.