Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NTP/4/SOURCE_LOST

NTP/4/SOURCE_LOST

Message

NTP/4/SOURCE_LOST: System synchronization source lost.

Description

The source reference clock was lost.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

This log message was generated when the current source reference clock was lost because of some reasons and no candidate reference clock can be found.

Procedure

  1. Check whether the network is normal.
  2. Run the display ntp-service sessions command to check whether candidate reference clocks exist.
    1. If candidate reference clocks exist, perform Step 3.
    2. If candidate reference clocks does not exist, run the ntp-service unicast-peer ip-address command or the ntp-service unicast-server ip-address command to configure the source reference clock.
  3. Run the display ntp-service status command to check whether the server status is stable.
    1. If the server status is stable, perform Step 4.
    2. If the server status is unstable, perform Step 5.
  4. Run the display clock command to check whether the system clock is normal.
    1. If the clock of the hardware is normal, perform Step 6.
    2. If the clock of the hardware is abnormal, perform Step 5.
  5. Contact Huawei technical support personnel.