ES3000 V3 NVMe PCIe SSD User Guide 20

This document provides the product information about the Huawei ES3000 V3 PCIe SSD (ES3000 V3 for short) and describes how to install, configure, operate, and maintain the ES3000 V3.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying the Namespace Distribution of an SSD

Querying the Namespace Distribution of an SSD

Function

This command is used to query the namespace distribution of an SSD.

Format

hioadm namespace -d devicename

Parameters

Parameter Description Value
devicename Name of a device Example: nvme0

Usage Guidelines

None

Example

# Query the namespace distribution of the nvme0 SSD.

[root@localhost tool]# hioadm namespace -d nvme0
total capacity: 1.8T 
unallocated capacity: 1.0T 
maximum capacity to creat single namespace: 800.0G 
namespace id    capacity    shared    controller id 
1               200.0G      NO        1 
2               600G        NO        N/A 

System Response

Parameter

Parameter Description

Value

total capacity

Total SSD capacity with one decimal place. Unit: GB or TB.

Example: 1.8TB

unallocated capacity

Unallocated SSD capacity with one decimal place. Unit: GB or TB.

Example: 1.0TB

maximum capacity to creat single namespace

Maximum capacity (with one decimal place) of a single namespace. Unit: GB or TB.

Example: 800.0GB

namespace id

All namespace IDs of an SSD.

Example: 1

capacity

Capacity (one decimal place) of a namespace. Unit: GB or TB.

Example: 200.0.0GB

shared

Whether the namespace is shared. The value is no.

no

controller id

IDs of controllers attached to a namespace.

Example: 1