Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Do I View Information Such as Interface Status and Packet Statistics?

How Do I View Information Such as Interface Status and Packet Statistics?

Run the display this interface command in the interface view to check the physical status, protocol status, traffic statistics, and the number of dropped packets of the interface.

NOTE:
  • When receiving or sending jumbo frames, the CE6880EI adds the number of jumbo frames to the jumbo frame statistics, and also add the number to the corresponding unicast, multicast, or broadcast packet statistics.

  • For the CE6880-48S4Q2CQ-EI and CE6880-48T4Q2CQ-EI, meanings of the following fields differ from those on other switches:
    • The Total Error field displays --. CRC indicates the number of packets with length exceeding 64 bytes and incorrect FCS values. Giants indicates the number of received packets with length exceeding the maximum jumbo frame size. Runts indicates the number of received undersized frames. The values of Jabbers and Fragments are 0.
    • For 10GE1/0/1 to 10GE1/0/12 on the CE6880-48S4Q2CQ-EI and CE6880-48T4Q2CQ-EI, the Jumbo field under the Output field displays --.
  • For CE6865EI, Giants indicates the number of received packets with length exceeding the maximum jumbo frame size.

  • When the last five GE interfaces (interfaces 43 to 47) on the CEL48GTEGA-E card receive Runts or Giants error packets, the system adds the number of received packets to the Runts or Giants field, and also adds the number to the corresponding Unicast, Multicast, or Broadcast field.

<HUAWEI> system-view
[~HUAWEI] interface 10ge 1/0/1
[~HUAWEI-10GE1/0/1] display this interface
10GE1/0/1 current state : UP
Line protocol current state : UP
...
Statistics last cleared:never
    Last 300 seconds input rate: 593 bits/sec, 0 packets/sec
    Last 300 seconds output rate: 4828451 bits/sec, 128 packets/sec
    Input peak rate 620 bits/sec, Record time: 2012-07-26 19:16:19
    Output peak rate 4862289 bits/sec, Record time: 2012-07-27 03:32:28
    Input :     10392642 bytes,        61627 packets
    Output:  60604323384 bytes,     13112586 packets
    Input:
      Unicast:                      0,   Multicast:                   63762
      Broadcast:                    0,   Jumbo:                           0
      Discard:                     0,   Frames:                          0
      Pause:                        0

      Total Error:                  0
      CRC:                          0,   Giants:                          0
      Jabbers:                      0,   Fragments:                       0
      Runts:                        0,   DropEvents:                      0
      Alignments:                   0,   Symbols:                         0
      Ignoreds:                     0

    Output:
      Unicast:                      0,   Multicast:                    2063
      Broadcast:                    0,   Jumbo:                           0
      Discard:                     0,   Buffers Purged:                  0
      Pause:                        0

    Input bandwidth utilization threshold : 90.00%
    Output bandwidth utilization threshold: 90.00%
    Last 300 seconds input utility rate:  0.01%
    Last 300 seconds output utility rate: 0.01%
Table 15-1  Parameters

Field

Description

current state

Physical status of the interface.

Line protocol current state

Protocol layer status of the interface Link layer protocol status of the interface.

Last 300 seconds input rate

Incoming packet rate (bits per second and packets per second) within the last 300 seconds.

Last 300 seconds output rate

Outgoing packet rate (bits per second and packets per second) within the last 300 seconds.

Input

Total number of packets received by the interface

Output

Total number of packets sent by the interface

Discard

Number of packets discarded by the interface