Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Disabling the ZTP Process

Disabling the ZTP Process

After an unconfigured device is powered on, it repeatedly executes the ZTP process. You can log in to the device through the Console port and press CTRL+C to terminate the ZTP process.

In V100R006C00 and later versions, you can run the set ztp disable command in the user view to disable the ZTP process so that a device does not execute the ZTP process after being powered on.

<HUAWEI> set ztp disable