Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring sFlow Agent and sFlow Collector

Configuring sFlow Agent and sFlow Collector

The Sampled Flow (sFlow) system involves an sFlow agent embedded in a Huawei switch and a remote sFlow collector. The sFlow agent obtains traffic statistics from an interface using sampling and encapsulates them into sFlow packets. The collector analyzes the sFlow packets received from the agent and displays traffic statistics in a report.

# Set the IP addresses of an sFlow agent and collector to 10.1.1.1 and 10.1.2.1 respectively, and set the sFlow packet sending mode to enhanced. Retain the default packet length 1400.
<HUAWEI> system-view
[~HUAWEI] sflow agent ip 10.1.1.1
[*HUAWEI] sflow collector 1 ip 10.1.2.1 enhanced
[*HUAWEI] commit
NOTE:

The enhanced mode is supported by only CE12800. In V100R005C10 and V100R005C00 versions, the enhanced mode is recommended when the collector is located on the network connected to a service port. In the enhanced mode, the switch sends sFlow packets to the collector through service cards. In V100R006C00 and later versions, you do not need to configure the enhanced mode. The switch will determine to send sFlow packets through service cards or management port based on the routing information on the collector.

In the enhanced mode, the switch cannot send sFlow packets through the management port.