Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring an FC Interface

Configuring an FC Interface

Before configuring an FC interface, connect an FC optical module to the FC interface. If the LINK indicator is steady green, the FC interface is Up.

# Switch 10GE1/0/1 to an FC interface.

<HUAWEI> system-view
[HUAWEI] port mode fc 10ge 1/0/1
Warning: This operation will cause all the other configurations on the port to be lost. Continue? [Y/N]:y
[*HUAWEI] commit

# After the FC interface is configured, check the FC interface status. When the physical status and link protocol status of the FC interface are both Up, the interface works normally.

[~HUAWEI] display interface fc 1/0/1
FC1/0/1 current state : UP (ifindex: 144)
Line protocol current state : UP
......