No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Common Operation Guide

CloudEngine 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Interval for Collecting Traffic Statistics on an Interface

Configuring the Interval for Collecting Traffic Statistics on an Interface

Run the set flow-stat interval interval-time command in the interface or system view to set the interval for collecting traffic statistics on an interface. The value of interval-time ranges from 10 to 600, in seconds. The value must be an integer multiple of 10 and the defaults to 300 seconds.

# Set the interval for collecting traffic statistics on 10GE1/0/1 to 400 seconds.
<HUAWEI> system-view
[~HUAWEI] interface 10ge 1/0/1
[~HUAWEI-10GE1/0/1] set flow-stat interval 400
[*HUAWEI-10GE1/0/1] commit
# Set the interval for collecting traffic statistics to 400 seconds in the system view.
<HUAWEI> system-view
[~HUAWEI] set flow-stat interval 400
[*HUAWEI] commit
  • The interval configured in the system view takes effect on all the interfaces that use the default interval.

  • The interval configured in the interface view takes effect only on this interface.

  • The interval configured in the interface view takes precedence over the interval configured in the system view.