Common Operation Guide

CloudEngine 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Layer3 Sub-interface

Configuring a Layer3 Sub-interface

CE12800 and CE7800 series switches support the Layer3 sub-interface configuration in V100R003C10 and later versions.

CE5800 series switches and CE6800 series switches (excluding the CE6810LI) support the Layer3 sub-interface configuration in V100R005C00 and later versions.

CE8800 series switches support the Layer3 sub-interface configuration in V100R006C00 and later versions.

CE12800E series switches support the Layer3 sub-interface configuration in V200R002C50 and later versions.

The following example shows how to configure a sub-interface.

<HUAWEI> system-view
[~HUAWEI] interface 10ge 1/0/1
[~HUAWEI-10GE1/0/1] undo portswitch             // Switch the interface to Layer 3 mode.
[*HUAWEI-10GE1/0/1] commit
[~HUAWEI-10GE1/0/1] quit
[~HUAWEI] interface 10ge 1/0/1.1              // Enter the Layer3 sub-interface view.