No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OceanStor 2200 V3 and 2600 V3 Storage System V300R005 Command Reference

"Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands."
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change hyper_metro_consistency_group general

change hyper_metro_consistency_group general

Function

The change hyper_metro_consistency_group general command is used to change the information about a HyperMetro consistency group.

Format

change hyper_metro_consistency_group general consistency_group_id=? { synchronization_rate=? | name=? | recovery_policy=? | description=? } *

Parameters

Parameter

Description

Value

consistency_group_id=? ID of the HyperMetro consistency group.

Run the "show hyper_metro_consistency_group general" command without parameters to obtain the value.

synchronization_rate=? Synchronization rate.

The value is "Low", "Middle", "High", or "Highest", where:

  • "Low": low rate.
  • "Middle": medium rate.
  • "High": high rate.
  • "Highest": the highest rate.
name=? Name of the consistency group.

The value contains 1 to 31 ASCII characters including digits, letters, underscores (_), hyphens (-), and periods (.), can only start with a digit or a letter.

recovery_policy=? Recovery policy.

The value is "automatic" or "manual", where:

  • "automatic":automatic recovery policy. Data will be automatically synchronized after faults are rectified.
  • "manual": manual recovery policy. Data needs to be manually synchronized after faults are rectified.
description=? Description of the HyperMetro consistency group.

The value contains 1 to 127 letters.

Level

Administrator

Usage Guidelines

OceanStor 2200 V3 storage system do not support this command.

Example

To change the synchronization rate of HyperMetro consistency group 1 to "Low", run the following command.

admin:/>change hyper_metro_consistency_group general consistency_group_id=1 synchronization_rate=Low
Command executed successfully.

System Response

None

Translation
Download
Updated: 2019-04-22

Document ID: EDOC1000106139

Views: 262251

Downloads: 178

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next