OceanStor 2200 V3 and 2600 V3 Storage System V300R005 Command Reference 06

"Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands."
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change performance strategy

change performance strategy

Function

The change performance strategy command is used to configure the policies of collecting system performance statistics.

Format

change performance strategy interval=? archive_enabled=? archive_time=? auto_stop_enabled=? [ duration=? ]

Parameters

Parameter

Description

Value

interval=? Interval between system performance statistics collections.

The value can be "5s", "10s", "30s", or "60s".

archive_enabled=? Whether to enable the automatic archiving function.

The value can be:

  • "yes": to enable the automatic archiving function.
  • "no": not to enable the automatic archiving function.
archive_time=? Archiving cycle.

The value can be "5s", "60s", "120s", "300s", "600s", "1800s", or "3600s".

auto_stop_enabled=? Whether to enable the function of automatically stopping performance statistics collection.

The value can be:

  • "yes": to enable the function of automatically stopping performance statistics collection.
  • "no": not to enable the function of automatically stopping performance statistics collection.
duration=? Maximum number of days to collect performance statistics.
NOTE:
When the "auto_stop_enabled=?" is set to "yes", this parameter is valid and must be specified
.

The value is an integer between 1 and 31.

Level

Administrator

Usage Guidelines

None

Example

To set the interval of collecting system performance statistics to "60s", enable the automatic archiving function, and set the maximum number of days to collect performance statistics to "1", run the following command:

admin:/>change performance strategy interval=60s archive_enabled=yes archive_time=60s auto_stop_enabled=yes duration=1
Command executed successfully.

System Response