OceanStor 2200 V3 and 2600 V3 Storage System V300R005 Command Reference

"Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands."
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change hyper_metro_pair general

change hyper_metro_pair general

Function

The change hyper_metro_pair general command is used to change HyperMetro attributes.

Format

change hyper_metro_pair general pair_id=? { recovery_policy=? | synchronization_rate=? } *

Parameters

Parameter

Description

Value

pair_id=? ID of the HyperMetro pair.

Run the "show hyper_metro_pair general" command without any parameters to obtain the value.

recovery_policy=? Recovery policy.

The value is "automatic" or "manual", where:

  • "automatic": automatic recovery policy. Data will be automatically synchronized after faults are rectified.
  • "manual": manual recovery policy.
Data needs to be manually synchronized after faults are rectified.
synchronization_rate=? Synchronization rate.

The value is "Low", "Middle", "High", or "Highest", where:

  • "Low": low rate.
  • "Middle": medium rate.
  • "High": high rate.
  • "Highest": the highest rate.

Level

Administrator

Usage Guidelines

OceanStor 2200 V3 storage system do not support this command.

Example

Change the pair synchronization rate to "Low" whoes pair ID is "1", run the following command.

admin:/>change hyper_metro_pair general pair_id=1 synchronization rate=Low
Command executed successfully.

System Response

None