No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OceanStor 2200 V3 and 2600 V3 Storage System V300R005 SmartVirtualization Feature Guide 07

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Dell Compellent SC30/SC40 Series

Dell Compellent SC30/SC40 Series

This section describes the precautions about configuration operations performed on the Dell Compellent SC30/SC40 series whose LUNs are hosted by the OceanStor 2200 V3/2600 V3.

  • The local storage system and Dell Compellent SC30/SC40 series (heterogeneous storage systems) support switch-connection networks only, instead of direct-connection networks.
  • Comply with the following rules upon zone division:
    • When zones are divided by port, allocate the primary port and reserved port of Dell Compellent SC30/SC40 series and ports of Huawei storage system to the same zone and all primary and reserved ports (on Dell Compellent SC30/SC40 series) that are connected to switches to another zone.
    • When zones are divided by WWN, allocate the primary port WWN of Dell Compellent SC30/SC40 series and port WWNs of Huawei storage system to the same zone and WWNs of all primary and reserved ports (on Dell Compellent SC30/SC40 series) that are connected to switches to another zone.
  • Set Operational Mode of ports of Dell Compellent SC30/SC40 series to Legacy Mode. Ensure that each Fault Domain contains one port of both controllers and Purpose is set to Front End Primary and Front End Reserved respectively.
    On the management interface of Dell Compellent SC30/SC40 series, choose System Management > System > Setup > Configure Local Ports. The Configure Local Ports dialog box is displayed. You can view and modify the desired information, as shown in Figure 10-1.
    Figure 10-1  Configure Local Ports dialog box

  • Click Create Server to create a host and set Operating System to Other Multipath.
NOTE:

For details about how to set parameters that are not mentioned in this section, see the related documents of the Dell Compellent SC30/SC40 series.

Translation