Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Impact and Restrictions

Impact and Restrictions

This section describes the restrictions on the SmartVirtualization feature.

Compatibility

Heterogeneous storage systems supported by SmartVirtualization can be Huawei storage systems and other third-party storage systems from mainstream vendors. Use the Huawei Storage Interoperability Navigator to check models of compatible Huawei storage systems and other mainstream vendors' storage systems.

Storage systems that are not listed in the interoperability matrix are incompatible heterogeneous storage systems. You are advised not to connect incompatible heterogeneous storage systems to a local storage system for takeover because incompatibility issues may occur. When you want to connect an incompatible heterogeneous storage system to a local storage system to meet service requirements, contact Huawei technical support.

Table 1-2 lists the connection methods between a local storage system and a compatible heterogeneous storage system.
Table 1-2  Connection methods between a local storage system and a compatible heterogeneous storage system

Heterogeneous Storage System

Connection Method

OceanStor Dorado5000 V3/Dorado6000 V3 storage system

Fibre Channel or iSCSI connection

OceanStor 2600 V3 (video surveillance edition) storage system

OceanStor 18500/18800/18800F/18500 V3/18800 V3/18500F V3/18800F V3 storage system

OceanStor 2200 V3/2600 V3/2600F V3 storage system

OceanStor 5300 V3/5500 V3/5600 V3/5800 V3/6800 V3/6900 V3/5500F V3/5600F V3/5800F V3/6800F V3 storage system

OceanStor S2200T/S2600T/S5500T/S5600T/S5800T/S6800T storage system

OceanStor S2900/S3900/S5900/S6900 storage system

OceanStor S2600 storage system

OceanStor S5300/S5500/S5600 storage system

OceanStor S6800E storage system

OceanStor S3100/S3200/S6800 storage system

Fibre Channel

Storage devices from mainstream vendors (for example, IBM DS4700 and EMC CX4-240)

Fibre Channel

If you create a masqueraded eDevLUN to take over a heterogeneous storage system non-disruptively, the operating system of your application server, multipathing software, and cluster software must meet compatibility requirements. For details, see Compatibility Requirements for an Online Takeover.