OceanStor 2200 V3 and 2600 V3 Storage System V300R005 SmartVirtualization Feature Guide 07

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NetApp FAS2000/FAS3000/V3000/FAS6000/V6000 Series And IBM N3000/N6000 Series

NetApp FAS2000/FAS3000/V3000/FAS6000/V6000 Series And IBM N3000/N6000 Series

This section describes the precautions about configuration operations performed on the NetApp FAS2000/FAS3000/V3000/FAS6000/V6000 series and IBM N3000/N6000 series whose LUNs are hosted by the OceanStor 2200 V3/2600 V3.

  • When creating a LUN, set Type of LUNs to Linux, or set LUN Protocol Type to Linux.
  • When creating a Initiator group, set Operating System to Linux, and select Enable ALUA, or run the igroup set [-f] <initiator_group> alua yes command on the CLI to enable ALUA.
  • Do not modify the WWNs of external LUNs when mapping them to the local storage system.
  • Do not set the external LUNs to the offline status when services are running.
  • The NetApp FAS3220/FAS3250/V3220/V3250/FAS6000/V6000 series support only C-Mode.
    • The type of a heterogeneous storage system's port that used to connect to the local storage system must be target. You can run the node run -node <node name> fcadmin config -t target <Adapter> command to check the port type.
    • The local storage system can only be connected to the heterogeneous system over the network using switches.
  • The other device models support only 7-Mode.
    • The type of a heterogeneous storage system's port that used to connect to the local storage system must be target. You can run the fcadmin config command to check the port type.
    • The value of cfmode must be single_image. You can run the fcp show cfmode command on the heterogeneous storage system to check the current mode.
    • The nodename of each controller must be the same. You can run the fcp nodename command on the heterogeneous storage system to check the current nodename value.
NOTE:

For details about how to set parameters that are not mentioned in this section, see the related documents of the NetApp FAS2000/FAS3000/V3000/FAS6000/V6000 series and IBM N3000/N6000 series.