No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OceanStor 2200 V3 and 2600 V3 Storage System V300R005 SmartVirtualization Feature Guide 07

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration Planning

Configuration Planning

Before centrally managing storage resources, make network and service plans to facilitate subsequent operations.

Network Planning

According to the requirement analysis, the OceanStor 2200 V3/2600 V3 needs to be deployed to host LUNs created on the EMC VNX5500, and the existing direct connection network needs to be restructured into a Fibre Channel switch connection network. Before configuring central resource management, the customer needs to connect the OceanStor 2200 V3/2600 V3 to the existing network. Figure 6-5 shows the new network.
Figure 6-5  New network

Table 6-8 lists the zones created to ensure normal communication among storage systems and application servers.
Table 6-8  Zoning

Zone Name

Included Node

Zone1

One IBM Power 740 server and the EMC VNX5500

Zone2

The other IBM Power 740 server and the OceanStor 2200 V3/2600 V3

Zone3

The EMC VNX5500 and the OceanStor 2200 V3/2600 V3

Service Planning

From the conclusions of the requirement analysis, it can be inferred that the university uses SmartVirtualization of the OceanStor 2200 V3/2600 V3 to take over the Oracle database services from the EMC VNX5500. Figure 6-6 illustrates the configuration roadmap.
Figure 6-6  Configuration roadmap

Table 6-9 describes the configuration operations and plan items.
Table 6-9  Configuration operations and plan items
Configuration Roadmap Major Operation and Purpose

Plan Item

GUI Parameter

Planned Value

Collect information before taking over database services.

  1. Collect the file system and disk information.
  2. Collect the database information.

None

None

None

Stop database services.

  1. Check the value of ASM diskstring.
  2. Stop all CRS services.
  3. Shut down the IBM Power 740 servers (Oracle hosts).

None

None

None

Delete the mappings between the heterogeneous storage system and the Oracle hosts.

Delete the LUN mappings between the EMC VNX 5500 and the Oracle hosts.

None

None

None

Check the license file for feature information.

Check the license file for the information about SmartVirtualization.

SmartVirtualization information in the license file

Feature

SmartVirtualization

Change the network.

Connect the OceanStor 2200 V3/2600 V3 to the existing network.

None

None

None

Create zones on Fibre Channel switches.

Zone names and nodes included in each zone

None

Planned based on Table 6-8.

Install Huawei UltraPath.

Install Huawei UltraPath on the Oracle hosts.

None

None

None

Set up a logical connection between storage systems.

Set up a logical connection between the OceanStor 2200 V3/2600 V3 and the EMC VNX5500.

None

None

None

Enable the OceanStor 2200 V3/2600 V3 to host LUNs created on the heterogeneous storage system.

Configure eDevLUNs on the OceanStor 2200 V3/2600 V3. The Oracle hosts employ the OceanStor 2200 V3/2600 V3 as a bridge to use the LUN resources on the EMC VNX5500.

  • Remote device name corresponding to the EMC VNX5500
  • WWNs of the LUNs mapped to the OceanStor 2200 V3/2600 V3 for hosting purposes
  • Names of eDevLUNs to be created
  • Storage pool to which eDevLUNs belong
  • Name (of a remote device)
  • WWN (of a remote LUN)
  • Name (of an eDevLUN)
  • Owning Storage Pool
  • Storage Medium and RAID Policy
  • Capacity (of a storage pool)
  • EMC VNX5500
  • 60:02:2A:11:00:06:8d:fe:07:a4:26:00:00:00:73 and 60:02:2A:11:00:06:8d:f43
  • eDevLUN_VNX1 and eDevLUN_VNX2
  • StoragePool1
  • Performance tier (composed of SAS disks) with RAID 5 (4D+1P)
  • 1 TB

Enable the Oracle hosts to scan for LUNs.

None

None

None

Translation