Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
When the Physical Connection Is Changed Between NetApp FAS3000 Series/FAS6000 Series/FAS8000 Series/NetApp E Series/TOYOU iSUM780/iSUM850/Fujitsu DX100 S3/DX200 S3/DX500 S3/DX600 S3 and the Local Storage System, the Link Is Down

When the Physical Connection Is Changed Between NetApp FAS3000 Series/FAS6000 Series/FAS8000 Series/NetApp E Series/TOYOU iSUM780/iSUM850/Fujitsu DX100 S3/DX200 S3/DX500 S3/DX600 S3 and the Local Storage System, the Link Is Down

Symptom

NetApp FAS3000 series/FAS6000 series/FAS8000 series/NetApp E series/TOYOU iSUM780/iSUM850/Fujitsu DX100 S3/DX200 S3/DX500 S3/DX600 S3 is connected to the local storage system through a Fibre Channel switch. When the physical connection is changed (the optical fiber is connected to a different port of the switch or the optical fiber is moved from one port of the heterogeneous storage system to another) between the NetApp FAS3000 series/FAS6000 series/FAS8000 series/NetApp E series/TOYOU iSUM780/iSUM850/Fujitsu DX100 S3/DX200 S3/DX500 S3/DX600 S3 and the switch, the link cannot be detected on DeviceManager of the local storage system even though the physical connection works properly.

Possible Causes

NetApp FAS3000 series/FAS6000 series/FAS8000 series/NetApp E series/TOYOU iSUM780/iSUM850/Fujitsu DX100 S3/DX200 S3/DX500 S3/DX600 S3 automatically detects the status of the connection between its port and the local storage system port. If an inconsistency is found, NetApp FAS3000 series/FAS6000 series/FAS8000 series/NetApp E series/TOYOU iSUM780/iSUM850/Fujitsu DX100 S3/DX200 S3/DX500 S3/DX600 S3 refuses the connection, causing the link to become unreachable.

Procedure

  1. Remove and then insert the cable, or modify the port rate of the local storage system.

    NOTE:

    This operation is performed on the switch port where the fiber channel is connected.

  2. On DeviceManager of the local storage system, check whether the link can be detected.

    • If yes, no further action is required.
    • If no, keep the fault environment intact and contact Huawei technical support.