No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OceanStor 2200 V3 and 2600 V3 Storage System V300R005 SmartVirtualization Feature Guide 07

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HP MSA2012FC/MSA2212FC

HP MSA2012FC/MSA2212FC

This section describes the precautions about configuration operations performed on the HP MSA2012FC/MSA2212FC whose LUNs are hosted by the OceanStor 2200 V3/2600 V3.

  • For a standard direct-connection network, set the link mode to loop, as well as Internal Host Port Interconnect to Interconnected to enable the internal switch mechanism.
  • For a standard switched network, set the link mode to loop or Point to Point, as well as Internal Host Port Interconnect to Straight-through to disable the internal switch mechanism.
    NOTE:

    Changing modifying the link mode, remove and reinsert the cables.

  • Do not change the owning controller of virtual disks
NOTE:

For details about how to set parameters that are not mentioned in this section, see the related documents of the HP MSA2012FC/MSA2212FC.