OceanStor 2600 V3 Storage System V300R005 HyperMetro Feature Guide 06

"This document describes the implementation principles and application scenarios of theHyperMetro feature. Also, it explains how to configure and manage HyperMetro."
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Starting a HyperMetro Consistency Group Forcibly

Starting a HyperMetro Consistency Group Forcibly

After system failure or the problem of the quorum server cannot which is prior service site is fixed, determine local site or remote site to provide service by starting the HyperMetro consistency group forcibly.

Prerequisites

  • The Running Status of the consistency group you want to pause must be Paused, Force Start or To be synchronized.
  • To ensure data security, shut down the service host and disconnect it from the quorum server before forcibly starting HyperMetro pair consistency group. After the HyperMetro pair consistency group is started, restart the service host and reconnect it to the quorum server.

Procedure

  1. Log in to DeviceManager.
  2. Choose Data Protection > HyperMetro > HyperMetro Pair > HyperMetro Consistency Group.
  3. Select the HyperMetro consistency group you want to forcibly start, and choose More > Force Start.

    The security alert dialog box displayed.

  4. Confirm the operation of forcibly start the HyperMetro consistency group.

    1. Carefully read the contents of the dialog box. Then click the check box next to the statement I have read and understand the consequences associated with performing this operation and click OK to confirm the information.

      The Execution Result dialog box is displayed indicating that the operation is successful.

    2. Click Close.