Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing a RAID Controller Card (Switch Module)

Installing a RAID Controller Card (Switch Module)

Scenarios

Install a RAID controller card in a switch module in any of the following scenarios:

  • A RAID controller card has failed.
  • A RAID controller card needs to be replaced with a new model.

Prerequisites

Conditions

No special condition is required for this operation.

Data

No data preparation is required for this operation.

Tools

  • ESD gloves
  • Packaging materials, for example, an ESD bag
  • Phillips screwdriver

Hardware

Spare RAID controller card

Procedure

  1. Power off the entire SCE or REE where a RAID controller card is to be installed. For details, see Powering Off the 9016.
  2. Remove the switch module. For details, see Removing a Switch Module.
  3. Remove the air duct from the switch module. For details, see Removing an Air Duct.
  4. Take the spare RAID controller card out of its ESD bag.
  5. Align the connector on the RAID controller card with the port on the mainboard, and gently insert the RAID controller card into the connector on the mainboard. See step (1) in Figure 6-137.
  6. Align the supercapacitor with the RAID control card, and tighten the screws. See step (2) in Figure 6-137.

    Figure 6-137 Installing the RAID controller card

  7. Place the cover onto the switch module. See step (1) in Figure 6-138.
  8. Gently push the cover until it snaps into place. See step (2) in Figure 6-138.

    Figure 6-138 Installing the switch module cover