KunLun 9016 V100R001 User Guide 12

This document describes the appearance, specifications, parameters, and structure of the KunLun 9016, and how to install an OS, replace parts, and install, remove, configure, and troubleshoot the server.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Sensor List

Sensor List

Table C-1 Sensor list

Sensor

Description

Remarks

SYS 1.1V

Mainboard 1.1 V voltage

N/A

SYS 1.5V

Mainboard 1.5 V voltage

SYS 3.3V

Mainboard 3.3 V voltage

SYS 5V

Mainboard 5.0 V voltage

SYS 12V

Mainboard 12 V voltage

Standby 1.2V

Mainboard standby 1.2 V voltage

Standby 3.3V

Mainboard standby 3.3 V voltage

Standby 5V

Mainboard standby 5.0 V voltage

PCH Temp

PCH temperature

PBI board

BIO Temp

Air inlet temperature of the rear I/O board

Rear I/O board

LedBoard Temp

LED transfer board temperature

LED transfer board

CpuBrdN Temp

CPU board temperature

CPU board. N indicates the CPU board ID, ranging from 1 to 8.

CPUN Core Rem

CPU core temperature

CPU.

N indicates the CPU ID, ranging from 1 to 4.

CPUN DTS

CPU DTS value

CPUN Prochot

CPU Prochot

Heartbeat

Heartbeat sensor

N/A

RTC Battery

RTC battery status

An alarm is generated when the voltage is lower than 1 V.

PCIE Status

PCIe status error

ACPI State

ACPI status

SysFWProgress

System software process and system startup error

Power Button

Power button

Left mounting ear

SysRestart

System restart cause

N/A

Boot Error

Boot error

Watchdog2

Watchdog

Mngmnt Health

Management subsystem health status

UID Button

UID button status

Left mounting ear

PwrOk Sig. Drop

Voltage drop status

N/A

PwrOn TimeOut

Power-on timeout

CPUN Status

CPU status check

CPU. N indicates the CPU ID. The value is 1 to 4.

CPUN Memory

DIMM status check

DIMM. N indicates the CPU ID. The value is 1 to 4.

CPUN QPI Link

CPU QPI link fault diagnosis health status

N/A

N indicates the ID of the component.

CPUN Core

Faulty CPU core that is isolated

CPU. N indicates the CPU ID, ranging from 1 to 8.

MemBrdN DIMM

Status of a memory module on the memory board module (MBM)

MBM. N indicates the MBM ID, ranging from 1 to 8.

MemBrdN Mig

MBM migration status

RAIDN Status

RAID controller card health status

N/A

N indicates the ID of the component.

RAIDN PCIE ERR

RAID card fault diagnosis health status

K1GPUN Temp

GPU temperature

K2GPUN Temp

GPU temperature

K10GPUN Temp

GPU temperature

K20XGPUN Temp

GPU temperature

K20CGPUN Temp

GPU temperature

K20MGPUN Temp

GPU temperature

M2090GPUN Temp

GPU temperature

5110PGPUN Temp

GPU temperature

K40MGPUN Temp

GPU temperature

P100GPUN Temp

GPU temperature

RAIDN Temp

RAID controller card temperature

CPUN MEM Temp

CPU DIMM temperature

DIMM.

N indicates the CPU ID. The value ranges from 1 to 4.

SD1 CARD

Check SD card health status

N/A

SD2 CARD

Check SD card health status

No SD Card

No SD card detected

CXPCable N

CXP cable lane drop or link down error

CXP cable. N indicates the ID of the owning component.

CXPCable LNKN

CXP link down

NCBoard Stat1

50% bandwidth decrease and ECC errors occurred on the NC chip

NC board

NCBoard Stat2

SEV2 fault occurred on the NC chip

NC Chip Temp

NC chip temperature

NC In Temp

Air inlet temperature of the NC board

NC Out Temp

Air exhaust vent temperature of the NC board

FRU Hot Swap

Hot swap status

N/A

NICN Status

NIC fault diagnosis health status

N/A

N indicates the ID of the component.

System Notice

Hot restart notice

Collect error information for the fault diagnosis program.

N/A

System Error

System suspension or restart.

Check the background logs.

PCH Status

PCH chip fault diagnosis health status

BMC Boot Up

BMC startup event

SEL Status

SEL full or clearing events

Op. Log Full

Operation log full or clearing events

Sec. Log Full

Security log full or clearing events

PCIEN Button

Button of the hot swap slot

Rear I/O board. N indicates the ID of the owning component.

SSDN Temp

ES3000 V2 temperature

N/A

N indicates the ID of the component.

SSDN Temp

ES3000 V3 temperature

BIO 12V

Voltage of the BIO board in the compute enclosure is 12.0 V.

N/A

NC 12V

Voltage of the NC board is 12.0 V.

N/A

MEMBrdN Temp

MBM temperature

MBM. N indicates the MBM ID, ranging from 1 to 8.

##9765Temp

9765 chip temperature. ## are the seven 9765 chips FA, FB, FC, SA, SB, SC, and SD. FB, SC, and SD are on PBI1. FA, FC, SA, and SB are on PBI2.

N/A

## 1.8V

9765 chip 1.8 V digital voltage. ## are the seven 9765 chips FA, FB, FC, SA, SB, SC, and SD. FB, SC, and SD are on PBI1. FA, FC, SA, and SB are on PBI2.

## 1.8V A

9765 chip 1.8 V analog voltage. ## are the seven 9765 chips FA, FB, FC, SA, SB, SC, and SD. FB, SC, and SD are on PBI1. FA, FC, SA, and SB are on PBI2.

## 0.9V

9765 chip 0.9 V digital voltage. ## are the seven 9765 chips FA, FB, FC, SA, SB, SC, and SD. FB, SC, and SD are on PBI1. FA, FC, SA, and SB are on PBI2.

## 0.9V A

9765 chip 0.9 V analog voltage. ## are the seven 9765 chips FA, FB, FC, SA, SB, SC, and SD. FB, SC, and SD are on PBI1. FA, FC, SA, and SB are on PBI2.

REE BION 12V

BIO board 12.0 V voltage

Hdd Max Temp

In 24-disk mode, this value indicates the highest HDD temperature. In other modes, this value indicates the highest disk temperature.

disk

SSD Max Temp

In 24-disk mode, this value indicates the highest SSD temperature.

SSD disk

Table C-2 Sensors only on the PBI2 (primary BMC)

Sensor

Description

Remarks

Inlet Temp

Air inlet temperature

Left mounting ear

FANN F Speed

Fan speed

Fan module. N indicates the fan module ID. The value ranges from 1 to 8.

FANN R Speed

Power

Server input power

N/A

PowerN

PSU input power

N/A

N indicates the ID of the component.

FANN F Status

Fan fault status

Fan module. N indicates the fan module ID. The value ranges from 1 to 8.

FANN R Status

FANN Presence

Fan presence

PSN Status

PSU fault status

PSU. N indicates the PSU ID. The value is 1 to 4.

PSN Fan Status

PSU fan fault status

PSN Temp Status

PSU presence status

PSU Configure

Only one PSU detected in the compute enclosure

IOBrd Inlet Temp

Air inlet temperature of the I/O enclosure

I/O enclosure

PCIe RAIDN Temp

PCIe RAID controller card temperature

N/A

M2 Temp(PCIeN)

Maximum temperature of all M.2 drives of the RAID controller card

N/A

Table C-3 Sensors only on the PBI1 (secondary BMC)

Sensor

Description

Remarks

FioInlet M Temp

Temperature in the middle of the air inlet on the front I/O board

Front I/O board.

FioInlet R Temp

Temperature on the right of the air inlet on the front I/O board

FioInlet L Temp

Temperature on the left of the air inlet on the front I/O board

HDDBkp9 Temp

Temperature nearby the hard disk backplane in slot 9

Hard disk backplane.

HDDBkp0 Temp

Temperature nearby the hard disk backplane in slot 0

HDDBkp2 Temp

Temperature nearby the hard disk backplane in slot 2

DISKN

Disk status

Hard disk. N indicates the physical disk slot number.

BkpB MISC Cable

Check disk backplane signal cabling B

N/A

N indicates the ID of the component.

BkpC MISC Cable

Check disk backplane signal cabling C

Bkp MISC Cable

Check disk backplane signal cabling

EXPN Status

Expander status

BMC Time Hopping

Time hopping

NTP Sync Failed

NTP synchronization failure and recovery events