Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing a BIO

Installing a BIO

Scenarios

Install a back I/O module (BIO) in any of the following scenarios:

  • A BIO has failed.
  • A non-hot-swappable PCIe card on a BIO has failed.

Prerequisites

Conditions

The 9016 SCE supports two types of BIOs: BIO-A and BIO-B. A BIO-A supports two standard hot-swappable PCIe slots, and a BIO-B supports three standard non-hot-swappable PCIe slots. This topic describes how to install a BIO-B.

Data

No data preparation is required for this operation.

Tools

  • ESD gloves
  • Packaging materials, for example, an ESD bag

Hardware

Spare BIO-B

Procedure

  1. Power off the physical partition where a BIO-B is to be installed. For details, see Powering Off the 9016.
  2. Take the spare BIO-B out of its ESD bag.
  3. Install all PCIe cards in the BIO-B. For details, see Installing a Non-Hot-Swappable PCIe Card. For details about how to install hot-swappable PCIe cards in a BIO-A, see Installing a Hot-Swappable PCIe Card.
  4. Insert the BIO-B into the SCE as far as it will go. See step (1) in Figure 6-40.
  5. Close the BIO-B ejector lever until the BIO-B is latched. See step (2) in Figure 6-40.

    Figure 6-40 Installing a BIO-B