KunLun 9016 V100R001 User Guide 12

This document describes the appearance, specifications, parameters, and structure of the KunLun 9016, and how to install an OS, replace parts, and install, remove, configure, and troubleshoot the server.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

Table 2-38 describes the technical specifications for the 9016.

Table 2-38 Technical specifications

Category

Item

Specifications

Mechanical specifications

Cabinet dimensions (H x W x D)

  • With cabinet and acoustic doors (H x W x D): 2000 mm x 600 mm x 1550 mm
  • 9016Without cabinet: CME (H x W x D): 86.1 mm x 447 mm x 750 mm, SCE (H x W x D): 325.4 mm x 447 mm x 840 mm, REE (H x W x D): 175 mm x 447 mm x 790 mm

Weight

  • With cabinet and acoustic doors: ≤ 760 kg in full configuration
  • Without cabinet:
    • SCE weight: ≤ 153 kg in full configuration
    • CME weight: ≤ 25 kg in full configuration
    • REE weight: ≤ 60 kg in full configuration

The weight depends on the actual hardware configuration.

Cabinet packaging: 130 kg (286.65 lb)

Acoustic door packaging: 44 kg (97.02 lb)

Environmental specifications

Temperature

  • Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A2 and A3 compliant)
  • Storage temperature: -40°C to +65°C (-40ºF to +149ºF)

Humidity

  • Operating humidity: 10% RH to 90% RH (non-condensing)
  • Storage humidity: 5% RH to 95% RH (non-condensing)

Altitude

≤ 3050 m (10006.56 in.)

According to the ASHRAE standards of 2015, for altitudes above 950 m (3116.79 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of:
  • 300 m (984.24 ft) in altitude when the server configuration complies with Class A2 standards.
  • 175 m (575.14 ft) in altitude when the server configuration complies with Class A3 standards.

Acoustic noise

The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

  • Idle:
    • LWAd: 6.7 Bels (with a cabinet and acoustic doors)
    • LpAm: 50 dBA (with a cabinet and acoustic doors)
  • Operating:
    • LWAd: 6.9 Bels (with a cabinet and acoustic doors)
    • LpAm: 53 dBA (with a cabinet and acoustic doors)
NOTE:

Actual sound levels generated during server operation vary depending on server configuration, load, and ambient temperature.

Power input specifications

External plug

Without cabinet: The CME is equipped with two power and fan integrity module (PFMs) using C13 PDU power cables. Each SCE can be equipped with two or four 3000 W AC power distributed units (PSUs) using C19 PDU power cables.

With cabinet:

  • The 9016 (without REEs) supports four IEC60309 32 A single-phase three-core industrial plugs, with dual AC power supplies in 2+2 redundancy mode; or two IEC60309 32 A three-phase five-core industrial plugs, with dual AC power supplies in 1+1 redundancy mode.
  • The 9016 (with REEs) supports six IEC60309 32 A single-phase three-core industrial plugs, with dual AC power supplies in 3+3 redundancy mode; or two IEC60309 32A three-phase five-core industrial plugs, with dual AC power supplies in 1+1 redundancy mode.

Input voltage

  • When configured with a cabinet, the 9016 supports IEC60309 32 A single-phase three-core industrial plugs (Each industrial plug supports an input voltage range of 200 V to 240 V AC at 50 Hz or 60 Hz, with up to 32 A input.) and IEC60309 32 A three-phase five-core industrial plugs (Each industrial plug supports an input voltage range of 346 V to 415 V AC at 50 Hz or 60 Hz, with up to 32 A input.)
  • When configured without a cabinet, the CME and SCE support an input voltage range of 90 V to 264 V AC at 50 Hz or 60 Hz.
    NOTE:

    The power supported by the PSU varies with the input voltage of the PSU. For details about power consumption of servers, see Huawei Server Power Calculator.

Power output specifications

Rated output voltage

The CME and SCE support an output voltage of 12 V DC.

The PDU and APD support an output voltage of 200 V to 240 V AC.

Power specifications

Maximum power consumption in typical configuration

The power consumption varies with the server module. Use the http://support.huawei.com/onlinetoolsweb/ftpa/en to calculate the power consumption.

Roller

-

The cabinet has four rollers at the bottom.

  • The four rollers are all castors.
  • The rollers can easily move at a slope of less than 10 degrees.
  • The static or dynamic load bear capability of a single roller is greater than or equal to 600 kgf.

Installation method

-

The server can be installed on:

  • ESD floor
  • Concrete floor