KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-2C00002B [LPM] Host Power-on Timed Out

ALM-2C00002B [LPM] Host Power-on Timed Out

Description

Alarm message:

The [LPM #] host power-on timed out. 

Attribute

Alarm ID

Alarm Severity

Auto Clear

2C00002B

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The server cannot be powered on.

Possible Causes

The intra-board power supply voltage is abnormal.

Procedure

  1. Check whether the external power supply meets the overall power consumption requirement of the server.

  2. Adjust the external power supply to have it meet the overall power consumption requirement. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Remove and reinstall the power supply units (PSUs), and power on the server. Then check whether the alarm is cleared.

  4. Replace the mainboard. Then check whether the alarm is cleared. For details about how to replace a mainboard, see the KunLun 90xx V100R001 User Guide.

  5. Contact Huawei technical support.