KunLun Mission Critical Server V100R001 CMC Alarm Handling 09

This document describes KunLun 9016 and 9032 alarms in the CMC, in terms of their meanings, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-17000021 The RTC Battery Voltage on the CMC Mainboard Is Lower Than the Undervoltage Alarm Threshold

ALM-17000021 The RTC Battery Voltage on the CMC Mainboard Is Lower Than the Undervoltage Alarm Threshold

Description

Alarm message:

The RTC battery voltage (xx V) on the CMC mainboard is lower than the undervoltage alarm threshold (xx V).

Attribute

Alarm ID

Alarm Severity

Auto Clear

17000021

Minor

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The system time of the CMC may be not correct, which will affect time-related services.

System Actions

None

Possible Causes

  • The lower threshold for minor alarms is not properly set for the sensor.
  • The RTC battery of the CMC has aged.

Procedure

  1. Run the smmget -t CMC RTC Battery -d thresholdall command on the CMC CLI, and check whether the lower threshold for minor alarms is set correctly.

    The proper threshold for the sensor is as follows:

    CMC RTC Battery: 2.79 V

  2. Run the smmset -t CMC RTC Battery -d lowernoncritical -v value command (value indicates the lower threshold for minor alarms) on the CMC CLI to change the lower threshold for minor alarms. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Run the reboot command to restart the CMC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Replace the CMC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Contact Huawei technical support.

Clearing

This alarm is cleared when the sensor detects that the voltage is higher than the lower threshold for minor alarms.

After the fault is rectified, the system automatically clears the alarm.