Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-38000001 CPU Connected to JC Chip Has a VMSE Error

ALM-38000001 CPU Connected to JC Chip Has a VMSE Error

Description

Alarm message:

The CPU# connected to [xxx] JC chip # has VMSE error.

Attribute

Alarm ID

Alarm Severity

Auto Clear

38000001

Minor

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

Server performance will be affected.

Possible Causes

  • A memory raiser is faulty.
  • The CPU is faulty.
  • The mainboard is faulty.

Procedure

  1. Check the memory raisers of the CPU one by one and replace the faulty memory raiser. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Replace the CPU. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Replace the mainboard. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Contact Huawei technical support.