Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-10000009 The Mainboard Voltage at the 12 V Detection Point Reaching the Undervoltage Threshold

ALM-10000009 The Mainboard Voltage at the 12 V Detection Point Reaching the Undervoltage Threshold

Description

Alarm message:

Mainboard voltage (xxx V) at 12 V detection point reaches the undervoltage threshold (xxx V). 

Attribute

Alarm ID

Alarm Severity

Auto Clear

10000009

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The system may stop responding.

Possible Causes

  • The mainboard is faulty.
  • The lower threshold for major alarms is not properly set for the sensor.

Procedure

  1. Remove the power cables to forcibly power off the server, and reinstall the power cables to power it on. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Run the smmget -l bladeN -t sensorname -d thresholdall command on the CMC CLI, and check whether the lower threshold for major alarms is set properly.

    The proper threshold for the sensor is as follows:

    SYS 12V: 10.80 V

  3. Run the smmset -l bladeN -t SYS 12V -d lowercritical -v value command (value indicates the lower threshold for major alarms) on the CMC CLI to change the threshold. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Replace the mainboard. Then check whether the alarm is cleared.

    For details about how to replace a mainboard, see the KunLun 90xx V100R001 User Guide.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Contact Huawei technical support.